Re: Turns out my BIG furnace filters are unnecessary?

Sep 02, 2010 23 Replies

I have never worked in FL, but here localy, I have had to show some of the inspectors in the code books where they were wrong.

I gave up on surface mount stuff cause my eyes just are not that good anymore. I still piddle from time to time with conventional parts and breadboards. Been thinking about getting back into some of the older digital modes on the HAM radio again. Sux that Radio Shack no longer carrys anything to do with radios or electronic parts. I remember building a packet modem for around $5 for my C-64 back in 1984.

Funny thing, that, I will be re-configuring and re-piping some chillers at a Jackson, MS TV station in a couple of weeks, to complete the change-over from the analog to digital transmitters, as well as to build in redundancy in the cooling systems. They still have an empty spot to add a 3rd digital transmitter, and cooling provisions are being made for that also.

I was hand soldering Motorola MC68340, 288 pin CPUs under a stereo microscope. QA couldn't tell my work from that done by the new Heller reflow oven. At first they tried to claim I didn't use enough solder because the rework department used more, till I picked up their IPCC handbook to show them that my work matched the photos, and it was rework who was using too much solder.

The fun thing is flushing them out to maintain water purity. The

1952 RCA used 25 pounds of Citric acid to remove the scaling once year, while the '80s 195 KW UHF Comark uses Tyglos which only works at full operating temperature and can not be used in the Klystrons. I needed some fiberglass duct board to enclose the sides of the chillers to use a salamander to heat the water, but no one wanted to sell it to me. The last place I asked was the local wholesaler. He told me to go to hell, so I told him I would make sure to mention their name on the TV station when we asked our members for help. Suddenly he thought it was a good idea to sell to a Christian TV station, gave me the best price break and loaded it into my truck. :)

BTW, I wrote software for a heating & air conditioning company in Ohio the mid '80s to calculate heat loss/loading for both new and upgrade jobs. It calculated each ceiling, door, window, wall and floor and printed a BOM, and estimated cost of operation in less than 15 minutes per job. I had three printers on the system, so you didn't load and unload forms all days.

Politicians should only get paid if the budget is balanced, and there is enough left over to pay them.

Not too worried about "water" purity here... the coolant is glycol, and I will be purging with N2 when doing the 1/2 dozen braze joints, the rest of the connections will use soft solder. This stuff is a little bit bigger than I normally work with.... 2" and 2 1/2" copper.

The RCA transmitter had 7 kV across the water. If purity wasn't maintained, it broke the water into hydrogen & oxygen which would over pressure the system.

That is small pipe, compared to the 4" and larger used in a TTU-25B

Politicians should only get paid if the budget is balanced, and there is enough left over to pay them.