Battery question

If I have a battery rated at 50AHours - does that mean it can supply

50A for 1 hour before it is dis-charged?

H

Reply to
HardySpicer
Loading thread data ...

50AH means the battery will supply 2.5 amps for 20 hours discharging down to 10.5 volts for a 12 volt lead acid battery.

For lead acid

formatting link

Bob

Reply to
<castlebravo242

In the ideal world, yes.

In the real world, no... most batteries are "rated" at their "C/10" rate, meaning that a 50Ah battery can supply 50/10=5 amps for 1*10=10 hours (=50Ah total). If you draw the "1C" rate (50A), you'll get noticeably less power out of it (

Reply to
Joel Koltner

No. That's a nominal rating. You'll need to look at the manufacturer's data sheet but the BCI rating system for lead-acid batteries specifies a discharge rate of 1/6 the AH rating for 6 hours (IIRC). So, you should be able to discharge at 8.3 A for at least 4.8 hours (80% rated capacity). The higher the discharge rate, the less you'll be able to pull from it; at 50 A, it's not going to last long.

--
Rich Webb     Norfolk, VA
Reply to
Rich Webb

The difference in energy extracted at high rates also depends on the battery construction. Batteries designed for high discharge rates do considerably better; batteries designed for way high capacity, with discharge rates sacrificed, will do considerably worse.

--
www.wescottdesign.com
Reply to
Tim Wescott

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.