code fragment causes error during bitstream generation... ISE 6.2 & Spartan3

hi ng, i get the following error-message during "Programming File Generation":

ERROR:Bitgen:145 - Pin M6 is a persistent pin, but a component exists in it's IOB. Please rerun par with the persistent pins prohibited from use. ERROR:Bitgen:157 - Bitgen will terminate because of the above errors. Error: bitgen failed Reason: Process "Programming File Generation Report" did not complete.

Here is the evil code fragment:

pIR : process (CLK, Reset) begin if Reset = '0' then Pending

Reply to
Stefan Oedenkoven
Loading thread data ...

Generation":

in

use.

[...]

here

in the

is only

big

Howdy Stefan,

Looks like this has been a problem in the past:

formatting link

option being set in BITGEN rather than PAR.

Good luck,

Marc

Reply to
Marc Randolph

Hi Marc,

we already use ISE 6.2.03i but still have this problem... and i still don't find this persist-option.... thanks, Stefan

Reply to
Stefan Oedenkoven