TEK 465

Mar 07, 2008 3 Replies

Can anyone give me a hint as to why my 465 is dead,no fan,no HV,,,I've repaired about 2500 crt monitors and around a couple dozen lcd's,,,just a clue anyone??done checked fuses,,, is there three or four???(just in case)......



DMM on top works fine.



Many,many,many, thanks Joe Smith West Point Monitor Repair


joesmith wrote in news:326d3cd9-4f5e-49d8-9e9f- snipped-for-privacy@m36g2000hse.googlegroups.com:

the DM44 has it's own separate power supply,from separate isolated windings of the power transformer.

First,you need to check the PS voltages and ripple.

After that,you will need to download schematics/service manual from the BAMA website.

Jim Yanik jyanik at kua.net

The commonest problem with 465 and similar Tek scopes seems to be power supply failure, due to shorted solid-tantalum capacitors, or dried-up (high-ESR or open) electrolytic cans.

formatting link
is a good place to start reading.

Dave Platt AE6EO Friends of Jade Warrior home page: http://www.radagast.org/jade-warrior I do _not_ wish to receive unsolicited commercial email, and I will boycott any company which has the gall to send me such ads!

snipped-for-privacy@radagast.org (Dave Platt) wrote in news: snipped-for-privacy@radagast.org:

I used to replace a lot of bad bridge rectifiers in them,too.

the BEST place to start reading is the TEK 465 service manual.

Jim Yanik jyanik at kua.net

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required