Mits WS-55859 Shutdown?

Hi group!

I'm trying to find the book of words/pictures for this set. It belongs to my client who brought it from the US. Mits in Canada can't supply any docs so I'm waiting to hear from Mits in the US. Until then, Set starts to come on, green led on front lights, HV comes up, then after about 1-2 secs, shuts down. I don't have to remove AC to reset. I'm hoping to avoid transporting this set. Any thoughts? Thanks!

Reply to
Bob Loblaw
Loading thread data ...

Press device and menu buttons for 5 sec simultaneously then count the flashes from LED for a 2 digit code. Post the results.

Leonard

Reply to
Leonard Caillouet

Hello Leonard:

Thank you very much for you help with this.

I had the customer follow these instructions. The code seems to be "22". It sounds like it keeps repeating.

Kevin.

Reply to
Bob Loblaw

Look for open fuses in the convergence supplies (+/-24v lines). If open you likely have a bad output IC. If not, check C9A60 on power bd (470 pF 1KV).

Leonard

Reply to
Leonard Caillouet

Leonard:

I had checked any fuses I could see the first time out but I missed F9A05 which is in the -24V line. It was open so I have ordered a convergence o/p IC. Thanks a lot for the help!!

Reply to
Bob Loblaw