Fuse substitution

Nov 17, 2008 3 Replies

This set uses two 3.5A 125V pico fuses in the convergence circuit. One is open. I don't have any pico fuses around the shop. After I replace the STK's would there be any harm in using a standard AGC or another fast blow 3.5A type in its place? Thanks, Lenny


On Nov 17, 10:49=A0am, " snipped-for-privacy@yahoo.com" wrote: > This set uses two 3.5A 125V =A0pico fuses in the convergence circuit. > One is open. I don't have any pico fuses around the shop. After I > replace the STK's would there be any harm in using a standard AGC or > another fast blow 3.5A type in its place? Thanks, Lenny

Mainly it will look clunky but function correctly. How do you attach to the 3AG ?

G=B2

How long can you wait for replacements? I recently bought Littelfuse picofuses from Mouser.

It will work fine as long as you can insulate it so that it can't short to anything, and if it doesn't matter how it looks. Andy Cuffe

snipped-for-privacy@gmail.com