CAN bus reply problems

Mar 21, 2005 4 Replies

Hi folks!



We are developing a system using the CAN bus to implement the network connecting different nodes. We have a PC that needs to ask for some data (the node status) to the nodes that have to answer to the request immediately. In order to ask each node for its status we send a "remote frame" message to the CAN bus with a specific ID. The relevant node has to answer with the relevant data by using a "data frame" message. Each node is in a while loop reading a buffer and sending back data when necessary. Usually everything goes well but sometimes it happens that one of the nodes does not answer to the PC request, even if the request is sent to the bus (it is seen by another node and it can be seen by using an oscilloscope connected to the CAN bus lines). It seems the node do not see the message, it misses the interrupt for updating the buffer... We usually send a sequence of "remote frame" messages waiting every time for the answer: send ,waiting for answer, send, waiting, ... Even if we insert a sleep between a send and another, sometimes the messages are missed by a node... We modified the baud rate (from 500Kbit to 20Kbit) but the problem is not solved. We are using a T89C51CC03 micro-controller by ATMEL.



Have you ever experienced this problem? Any suggestion?



Thank you in advance for any help!



Cheers, Ska


1: This is either a problem with your microprocessor or with your code. 2: I have no experience with Atmel & CAN. 2a: The TMS320F2812 has been rock solid for me. 3: No protocol should trust external nodes 100% to receive something -- you should always have a timeout & retry mechanism.
Tim Wescott Wescott Design Services http://www.wescottdesign.com

I can not answer your specific question, in other words I don't know which part of your software or hardware is responsible for it. Could be the driver, could be a miss configuration of the CAN controllers, could be the cabling. But you should consider switching your node monitoring from the master/slave principle you are using now to something other. Your current implementation looks exactly like to _old_ CANopen Node Guarding mechanism. CANopen switched to Heart Beat years ago, where each node is an autonomously Heart Beat Producer and can be monitored by every node that wishes to do so. The benefit is more flexibility and reduced band width for the node monitoring. Anyway, it can happen that one of the Heart Beat Consumers is missing one Heart Beat of one of the Producers. In this case increase the rate or accept that one or more HB are missing.

Regards Heinz

with best regards / mit freundlichen Grüßen Heinz-Jürgen Oertel +=================================================================== | Heinz-Jürgen Oertel port GmbH http://www.port.de | mailto:oe@port.de | phone +49 345 77755-0 fax +49 345 77755-20 | Regensburger Str. 7b, D-06132 Halle/Saale, Germany | CAN Wiki http://www.CAN-Wiki.info | Newsletter: http://www.port.de/engl/company/content/abo_form.html+===================================================================

Hello Tim, hello Heinz, hello everybody

Thank you for your mails.

What you both are telling is that "No protocol should trust external nodes 100% to receive something -- you should always have a timeout & retry mechanism"! This is exactly what we are doing now, but it is something I don't like so much... :( We set a maximum number of retry messages (say 10) and it sometimes happens that the trials go over this threshold! In this case we reset and start again the CAN bus but, as I said, it is something we don't like so much...

...mmm...

Regards, Ska

[Massive quote without actual referral snipped. Please don't do that.]

What you're observing appears to be a rate of failure to receive CAN messages that is quite a lot beyond expectations of the protocol, unless you were operating in a pathologically noisy environment --- but you didn't mention anything like that.

What this hints at is a genuine bug in the receiving end, but I'm afraid you didn't reveal enough of its details for anybody out here to be able to remote-diagnose it more precisely. So I'll just bombard you with some questions:

Did you test this with only two nodes on the bus, and check if the receiving one ACKs the transmission?

What *is* the rate of failure, anyway, i.e. one in how many messages gets lost? What is the rate of transmissions with CRC or other failures, on the same network?

Do you have any way of debugging into the receiving CAN controller's register banks after a failed receival, to distinguish if the message actually failed to arrive in the message box, or just failed to raise the IRQ it's configured to? (There's a bug like that in another 8051 derivative with integrated CAN...)

Do you have a storage scope that would let you record the exact signalling up to the point of failure, so you could go look for any differences between successful and failing transmissions, on physical level?

Hans-Bernhard Broeker (broeker@physik.rwth-aachen.de) Even if all the snow were burnt, ashes would remain.