Reservation about UART1 FIFO in C8051F34x in MCE mode

I wrote a multi-processor serial bus protocol. It was to connect several F340 as slaves to one Cypress FX2LP as master. The master sent out a command byte with the ninth bit set which alerted the slaves to what was happening next. Interested slaves then participated in various ways (but only one sending, of course).

It was unreliable.

Stripped down to one master and one slave, it was still unreliable. Eventually, I had the slave's ISR pulse when it received anything and pulse when it received a command byte (ninth bit set). Because of the nature of the protocol we could also produce a pulse when an unexpected command byte was received.

On the scope we could see those pulses and also the serial line going into the F340. We could easily follow the traffic, bytes being received, and pulses happening. We post triggered on the "unexpected command byte". And there we had it. The software had received again a command byte it had received a few bytes earlier but which had not come in on Rx.

I changed the software in the F340 to use UART0 (no FIFO) and the problem went away.

We have reported this concern (that their FIFO is somehow re-issuing a command byte) to SiLab. They wanted me to move the master software to the PC and use PortMon (I'd have thought a scope trace was much more conclusive). Then they wanted a small test program.

But we have work to do, having lost time on this problem. The email is just a flag in case you see something like this. I had a difficult time nailing this as timing seemed to matter, so adding/subtracting debug made it move around. Eventually logging events to a memory buffer showed what to look for on the scope.

HTH

Bill

formatting link

Reply to
Bill Davy
Loading thread data ...

Does that 'few bytes' have any relation to the FIFO size, or fifo peak usage ?

Would this even start filling the fifo - ie a simple test like this should empty faster than it fills ?

-jg

Reply to
Jim Granville

The FIFO was never filling (ISR checked overflow). In fact, the FIFO was always empty or had at most a byte passing through. It is a three byte FIFO and the duplicated byte was about three bytes old. Sadly, I do not seem to have kept any log files and I cannot afford the time to go back and re-create the problem.

Bill

formatting link

Reply to
Bill Davy