Hvordan ældes ubrugte...

elektrolytkondansatorer? Er en ubrugt 10.000 myF anvendelig efter fx 15 år, fornuftigt opbevaret?

Mvh.

Per J

Reply to
qwert
Loading thread data ...

"qwert" wrote in news:44155355$0$11700$ snipped-for-privacy@nntp02.dk.telia.net:

For mange år siden var jeg på et kursus som ELFA (vistnok) afholdt, der fik vi at vide at 'lytter bør spændingssættes mindst en gang om året for at hindre en eller anden process i nedbryde dem.

Den process ville i givet fald give en overgang mellem "pladerne" så en pludselig spændingssætning ville medføre en punktformet kortslutning med risiko for stødkogning = PUFF.

Så jeg ville i dit sted prøve at sætte 10% af mærkespændingen til via en stor modstand (f.eks. 10 kOhm) og lade dem stå en tid, skrue lidt op osv. for at sikre dig mod det.

Mvh. NKJensen

Reply to
Niels Kristian Jensen

Hej Per

Find databladet og kik på Shelf life.

Mvh Max

Reply to
Max

De tørrer ud, dvs. elektrolytten fordamper. Om de kan lagres så længe ved jeg ikke, men du kan jo prøve at måle på den (op- og afladekurve), så kan du se om den er OK. /erlo

Reply to
erlo

Afhængig af type, og hvad den skal bruges til.

Men til andet end hobbyprojekter = smid dem ud.

Reply to
Ole Geisler

Hvis pakningen ikke er tæt - men ellers ikke.

Nej.

Reply to
Ole Geisler

=E5r,

Hej

Den "rigtige" metode er at m=E5le ESR (Equivalent Series Resistance) og=20 sammenligne den med andre lignende kondensatorer:

Capacitor Testing, Safe Discharging and Other Related Information Version 2.42 (22-Nov-05):

formatting link
Citat: "... Before I bought my ESR meter I too wondered--what exactly did it=20 measure? Nevertheless, having heard so much about the meter, I went=20 ahead and bought one. It works, and that's the real bottom line. =2E.. The objective of the ESR meter is to identify capacitors that have gone=20 bad. This is more the case with electrolytics where the dielectric=20 compound tends to dry up. =2E.."

formatting link

-

Bob Parker's ESR Meter Page (se ogs=E5 Mk2 kit):

formatting link

The electrolytic cap ESR problem, and this meter...by Bob Parker the=20 designer of the ESR Meter Kit (Mark 1):

formatting link
Citat: "... The real fault with many of these electros was not so much that their=20 capacitance had dropped (as many people assume), but their Equivalent=20 Series Resistance (ESR) had risen to a high value, seriously degrading=20 their effectiveness as filtering, bypassing and coupling components. =2E.."

Hints for techs using Bob Parker's ESR meter(kit)...:

formatting link
Citat: "...Bob Parker's excellent ESR meter (January 1996) will also=20 test all types of cells and batteries..."

-

Andre ESR-metre:

An Equivalent Series Resistance Meter (uden mikrocontroller):

formatting link
Citat: "...With my ESR meter I quickly found five electrolytic=20 capacitors which had degraded a lot...one had 6 Ohm, one 7 Ohm, and the=20 other two had such high ESR that the meter wouldn't even deflect!..."

mvh/Glenn

Reply to
Glenn Møller-Holst

Ikke nemt på en 10.000 uf...

Reply to
Anders Jacobsen

Anders Jacobsen skriver:

Hvorfor ikke ?

Klaus

--
    Sonofon, er de bare inkompetente ?
http://home6.inet.tele.dk/moppe/sononews.html
Reply to
Klaus D. Mikkelsen

Fordi ESR værdien er forsvindene lille.

Reply to
Anders Jacobsen

=20

Hej Anders

Hvis ESR er v=E6sentligt h=F8jere end f.eks. 0,2 ohm, er en 10.000 uF=20 kondensator t=F8rret noget ud. Er den meget lavere (

Reply to
Glenn Møller-Holst

Den kan da sagtens måles med Bob Parkers ESR meter :)

--
Mvh, Kim Voss Schrader
Reply to
Kim Voss Schrader

Kim Voss Schrader skriver:

Tak !

Klaus

--
    Sonofon, er de bare inkompetente ?
http://home6.inet.tele.dk/moppe/sononews.html
Reply to
Klaus D. Mikkelsen

det jeg mente var 0.04 er meget lavt, der skal ikke meget til før der kan komme en fejl læsning.

Reply to
Anders Jacobsen