Hockey puck SCRs

I recently bought a hockey-puck SCR, without realising it needs to be clamped to a heatsink. I'm trying to decide whether to return it or whether to build a mount.

The SCR in question is an Internation Rectifier 250PA140, specs pasted at the end of this topic.

First of all, I haven't managed to find any information about how much force you need to clamp these things with. I'm assuming 2 metal plates with 3x6mm bolts should be ample.

Secondly, do I need to apply force or displacement? For example, if I need to apply exactly 1mm of displacement to the plates of the puck, then the puck contracts by 0.1mm this might be a disaster, unless there is some kind of springy contact inside that will take up the slack. Perhaps I should use some kind of springy bar to apply a constant pressure despite changes in temperature etc...

Thirdly, I presume that too much force will break the die, and too little will mean the contact has insufficient area for the device to function properly? How can I know when I've tightened the clamp the right amount?

Finally, I understand there is meant to be a snubber resistor between the gate and the cathode. But I get very low resistances of < 0.1 ohm and I wonder whether this implies it is broken?

If I(GT) Max. is 150m and the parallel resistance is < 0.1 ohms then as I see it the voltage can't rise high enough to cause the device to trigger - I'm assuming it needs at least a diode drop.

Thanks in advance for any help.

K

V(DRM) Max.(V)Rep.Pk.Off Volt.=1.4k I(T) Max.(A) On-state Current=250? @Temp. (?C) (Test Condition)=70 I(TSM) Max. (A)=4.2k I(GT) Max. (A)=150m V(GT) Max.(V)=2.5 I(H) Max.(A) Holding Current=500m I(D) Max. (A) Leakage Current=11m @Temp. (?C) (Test Condition)=125 V(T) Max. (V)=2.3 @I(T) (A) (Test Condition)=250 dv/dt Min. (V/us)=200 t(q) Typ. (s)=60u Package=TO-200AB

Reply to
KW
Loading thread data ...

I found another device datasheet with TO-200AB. At the end of the datasheet, it says 700-900 lb, or 320-400 Kg.

formatting link

formatting link

I don't think you'd be looking at displacement for a ceramic case.

--
John
Reply to
John O'Flaherty

My old GE manual specifies 700-900lbs force for their press pak mounted SCRs. I mounted some where I didn't have to be concerned about dissipating heat (single pulse operation) and found an online calculator to determine clamping force resulting from a given torque on a bolt then used a small torque wrench to tighten it up. I don't remember the numbers, but it took surprisingly little torque to get 800lbs clamping force. You might try googling "presspack" to see what you come up with.

Mike When truth is absent politics will fill the gap.