Right. You only get millivolts out of these things.
John
Right. You only get millivolts out of these things.
John
If a load cell has a bridge of strain gages with sensibility of 2 mV/V, and I apply a V=5v, and the range of force is from 0 to100 Kg, is correct to say that with the max force applied the V difference should be 100 * 5
*2mV/V = 1V ?
--- No. What the 2mV/V means is that for every volt of excitation, the bridge will output 2 millivolts with the maximum rated mechanical load on the load cell. Like this:
k Vin Fin Vout = ----------- Fmax
where k is the rated sensitivity of the load cell in mV/V Vin is the excitation voltage Fin is the force exerted on the load cell Fmax is the load scale's full-scale force rating
In your case we'll have: 2mV ----- * 5V * 100kgF 1V Vout = ----------------------- 100kgF
which, after the V's and the 100kgF's cancel out leaves you with:
Vout = 2mV * 5 = 10mV
-- John Fields Professional Circuit Designer
Nononononono unless it's given as 2mV/V/kg (which it isn't)
The output at maximum load will be 2mV * 5 = 10mV.
Paul Burke
Force is correctly measured in Newtons ! To use the old fashioned way of talking ... 1 N = 1 kgf ( not 1 kg ) = 1kg*9.81m/s. F = ma. Check the sensitivity spec.
Other than that, your calculation seems ok
Graham