Furnace Electronic Air Cleaner

Mar 12, 2008 1 Replies

I have an electronic air cleaner on my furnace circa 1971, that doesn't work. When you turn it on - nothing happens.



I have an elementary knowledge of electronics (mechanical engineer). Parts are no longer available for this, but my guess is that it is a fairly simple device electronically. What parts are likely to fail just from age? It has two large capacitors and a transformer in the schematic that I have for it.



Thanks in advance for any suggestions for trouble shooting.


The usual circuit has a transformer, some kind of voltage-tripler (like a Cockcroft-Walton) rectifier, and sometimes a pilot lamp. There's also an interlock switch, so it turns off when the door to clean/change the filters is open.

Not much can go wrong, except dirty switch, shorted plates, or broken corona wires. The output voltage and impedance are beyond most electrical testers' capabilities, though. Clean up any dirt, check for applied power, and if the plates and filters get dirty again, it IS working.