ZCD New Thread

Feb 29, 2012 1 Replies

Using the components available in LTSpice. Could use some work. It is not original.


Version 4 SHEET 1 880 680 WIRE 768 -208 608 -208 WIRE -192 -112 -832 -112 WIRE -64 -112 -192 -112 WIRE 80 -112 -64 -112 WIRE 272 -112 160 -112 WIRE 352 -112 272 -112 WIRE 608 -96 608 -208 WIRE 352 -80 352 -112 WIRE 768 0 768 -208 WIRE 352 16 352 -16 WIRE -832 32 -832 -112 WIRE -192 32 -192 -112 WIRE -832 128 -832 96 WIRE -784 128 -832 128 WIRE -656 128 -704 128 WIRE -528 128 -576 128 WIRE -368 128 -448 128 WIRE -192 128 -192 96 WIRE -192 128 -288 128 WIRE -64 128 -64 -112 WIRE -16 128 -64 128 WIRE 96 128 48 128 WIRE 272 128 272 -112 WIRE 352 128 272 128 WIRE 608 128 608 -16 WIRE 608 128 544 128 WIRE -64 144 -64 128 WIRE -832 160 -832 128 WIRE -192 160 -192 128 WIRE 608 192 544 192 WIRE 768 192 768 80 WIRE 768 192 608 192 WIRE 96 224 96 128 WIRE 352 224 96 224 WIRE -832 272 -832 224 WIRE -192 272 -192 224 WIRE -192 272 -832 272 WIRE -64 272 -64 224 WIRE -64 272 -192 272 WIRE 608 288 608 192 WIRE -64 304 -64 272 FLAG 608 288 0 FLAG -64 304 0 FLAG 352 16 0 SYMBOL Optos\\MOC207 448 192 R0 SYMATTR InstName U1 SYMBOL cap 336 -80 R0 SYMATTR InstName C2 SYMATTR Value 4.7=B5 SYMBOL res -48 240 R180 WINDOW 0 36 76 Left 2 WINDOW 3 -44 16 Left 2 SYMATTR InstName R2 SYMATTR Value 10K SYMBOL voltage -688 128 R90 WINDOW 3 -276 62 Left 2 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V1 SYMATTR Value SINE(0 158 60 0 0 0 100) SYMBOL voltage 768 -16 R0 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V2 SYMATTR Value 5V SYMBOL res 592 -112 R0 SYMATTR InstName R1 SYMATTR Value 4.7K SYMBOL diode 48 112 R90 WINDOW 0 0 32 VBottom 2 WINDOW 3 -57 18 VTop 2 SYMATTR InstName D2 SYMATTR Value GSD2004W-V SYMBOL res 176 -128 R90 WINDOW 0 0 56 VBottom 2 WINDOW 3 32 56 VTop 2 SYMATTR InstName R3 SYMATTR Value 27K SYMBOL diode -816 96 R180 WINDOW 0 24 64 Left 2 WINDOW 3 24 0 Left 2 SYMATTR InstName D3 SYMATTR Value MURS120 SYMBOL diode -176 96 R180 WINDOW 0 24 64 Left 2 WINDOW 3 24 0 Left 2 SYMATTR InstName D4 SYMATTR Value MURS120 SYMBOL diode -816 224 R180 WINDOW 0 24 64 Left 2 WINDOW 3 24 0 Left 2 SYMATTR InstName D5 SYMATTR Value MURS120 SYMBOL diode -176 224 R180 WINDOW 0 24 64 Left 2 WINDOW 3 24 0 Left 2 SYMATTR InstName D6 SYMATTR Value MURS120 SYMBOL voltage -272 128 R90 WINDOW 3 -215 58 Left 2 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V3 SYMATTR Value SINE(0 53 180 0 0) SYMBOL voltage -432 128 R90 WINDOW 0 -32 56 VBottom 2 WINDOW 3 32 56 VTop 2 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V4 SYMATTR Value SINE(0 32 300) SYMBOL voltage -560 128 R90 WINDOW 0 -32 56 VBottom 2 WINDOW 3 32 56 VTop 2 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V5 SYMATTR Value SINE(0 1 11060) TEXT -866 322 Left 2 !.tran 0 500m 200m


Cute. Increasing C2 tightens up the timing.

--

John Larkin, President Highland Technology Inc

formatting link
jlarkin at highlandtechnology dot com

Precision electronic instrumentation Picosecond-resolution Digital Delay and Pulse generators Custom timing and laser controllers Photonics and fiberoptic TTL data links VME analog, thermocouple, LVDT, synchro, tachometer Multichannel arbitrary waveform generators

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required