Does this mean that we can now put vias inside surface mount pads?
Paste in Hole Process
Capillary action tends to suck out the solder and even balls on BGA. I have seen guidelines that capping the via with solder mask from the back side tends to prevent that, but is not reliable enough. Filling the via is possible but troublesome, so the recommendation was to avoid in-pad vias.
Late at night, by candle light, przemek klosowski penned this immortal opus:
I saw somewhere mentioned that with a fine enough drill the vias will plate shut. OTOH you'll have to talk nicely with the boardhouse since they don't appreciate it much.
- YD.
We put 4, 5, sometimes 7 into a power pad.
John
Part of the problem is that small amounts of the nasty acidic plating solution get trapped inside voids in the via. They tend to boil when you do the reflow, which is a Bad Thing.
Cheers,
Phil Hobbs
Join the Discussion
Have something to add? Share your thoughts — no account required.
Didn't find your answer?
Ask the community — no account required