Freaky Amazing DMM?!

d

- I

Right. It's easy to lower the effective impedance of a high=20 impedance meter. Going the other way is a lot harder.

Reply to
krw
Loading thread data ...

Doesn't need to get into the innards directly, you can screen that, but you've got a pair of leads forming an aerial and most likely a diode at the junction of the test lead and the DVM socket. A low impedance input attenuator will load that down to something insignificant compared with what you are measuring.

Reply to
Stuart

Late at night, by candle light, "David L. Jones" penned this immortal opus:

*over*

"HI-Z"

The circuits are loaded, so any bad contacts will certainly affect the reading. Which is the way I like it. Any funny readings, move up to the next point in the line and check there.

I do know better than to measure an unloaded line without sticking some suitable load across it.

Anyways, AIUI, this started with a meter with Hi-Z in the mV range, most DVMs use a 10M or 1M divider at higher ranges.

- YD.

--
File corruption detected. Select option:
1 - Call the cops
2 - Call the press
3 - Bribe it

Remove HAT if replying by mail.
Reply to
YD

In article , snipped-for-privacy@argonet.co.uk says...>

Nonsense. There are many things that can be done to eliminate any external factors. Add a shunt resistor and you have your low impedance meter.

Nonsense. If an input resistor will load down your circuit so will your low impedance meter. It's *exactly* the same thing, except the user gets the choice.

Reply to
krw

Go get some practical experience.

Reply to
Stuart

In article , snipped-for-privacy@argonet.co.uk says...>

I certainly have more than you.

Reply to
krw

r*

-Z"

This is an oft used but seldom understood saying. The reason a craftsman supposedly never blames his tools is because a craftsman tends to buy quality tools in the first place.

Reply to
Daniel

claims *over*

or "HI-Z"

Keithley has

10Mohms

a bit

will

I

what

Yes, electricians generally just do just the one similar job. That's why they make meters designed for just such specific purposes. Giving your average electrician say a Fluke 289 is a bit overkill and would likely not be as productive as a more job specific instrument.

That's why many good meters have selectable Low-Z and High-Z modes.

Dave.

Reply to
David L. Jones

Safely, in a dangerous situation? What part of using the right tool for the job don't you understand?

Yes, High-Z meters are good (more useful in more cases), but Low-Z meters have their place too. There simply isn't any argument here, if you need a Low-Z meter, use one. If you need a High-Z meter, use one. "Making do" without the right tool in serious situations is stupid.

Agreed. That's why if you have serious needs you either have a dual purpose meter, with Low-Z and High-Z modes, or you have two meters.

Dave.

Reply to
David L. Jones

Daniel wrote in news:e8f56b53-9c0c-49cd-b6b5- snipped-for-privacy@i24g2000prf.googlegroups.com:

I thought it was to do with a craftsman knowing the limits of his tools, thus not blaming them for over-reaching.

Related to that, I find the best definition of a toolmaker is one who achieves greater accuracy than was provided, and makes a system to easily repeat that gain.

Reply to
Lostgallifreyan

- I

It's easy to do safely.

What part of understanding electricity don't you understand?

If you're a sparky and all you do is wiring, sure. There is no reason to have a high impedance meter. That doesn't mean that a high impedance meter can't be used safely and accurately.

If you have a meter for every job, sure. If you don't, a little knowledge goes long way.

Nice snip. That's known as a lie in many corners.

No, you understand what you have and use it appropriately. ...something there is an obvious shortage around here.

Reply to
krw

claims *over*

impedance" or "HI-Z"

Keithley has

10Mohms

is a bit

they will

a

the

of

the

that I

what

more

That wasn't at issue here. The statement was made that a high impedance meter couldn't be used and that a low impedance *ANALOG* meter was a necessity. It's certainly not true, though one has to understand what one is doing, again a rarity in this group.

Most *good* meters don't. Many sparky meters might.

Reply to
krw

The antenna I get. A diode? Are you sure that you are familiar with modern multi-meter construction?

Low Z meters are dumbed down so that dopes can artificially SUPPRESS what they term as "noise" when reading power sources in an EMI rich environment, such that they can take "reasonably reliable" readings on a power source. They are NOT made for getting true reading on small signal sources in any way shape or form. The same thing can be accomplished by changing the sample rate or chop the input and average. The same canceling can also be gotten by twisting the meter leads together. Note that nearly all "sense line" attachments are of the twisted pair variety. There is a reason for that, and it is not so that the wires stay bundled together.

The Fluke Low Z model has the capacity to REMOVE the low Z shunt from the meter's lead-in circuit, giving the user back an actual, accurate, high Z meter.

Placing a shunt across your voltage measurement cannot be done on a source where such a low impedance will load the source. Either way, you get a flawed reading.

High impedance metrology is akin to actually getting the test data without touching or modifying the circuit. As we all know, this is a very hard thing to accomplish. High Z meters are a GOOD thing. Anyone that thinks they are not needs their head examined.

Reply to
Archimedes' Lever

*over*

"HI-Z"

Most modern meters are high Z on nearly every range.

Reply to
Archimedes' Lever

Loaded...

Unloaded...

Something stinks in here either way.

You have been out of the loop too long. Even your feedback has been self attenuated. No gain whatsoever.

Reply to
Archimedes' Lever

*over*

"HI-Z"

Metallic?

Reply to
krw

I

Who said anything about a dangerous situation? If a pro is taking a reading, his chosen job is not dangerous to him, and he knows how to take the reading properly. That is why certain skills are taught.

All low Z meters simply have their low Z rated value utilized as a direct shunt across the input leads. That is ALL low Z meters. That is how it is done... in EVERY CASE. SO it is NOT unsafe to CREATE your own low Z input by doing the same thing. You simply must ALSO be sure to observe and obey all proximity rules and exposed node precautions, like any pro would do anyway.

Low Z meters ARE high Z meters with a shunt. In almost every case, but the cheap Harbor Frieght crap.

Going from having high Z and getting low is not a problem. The other way is simple too. All you need to do is go buy a high Z meter.

A good "low Z meter" will allow turning the shunt off. Shitty brands do not.

Get a good, High Z meter, and if you need Low Z input impedance, set it up right and perform you measurements. It really is that simple. Proper set-up.. proper reading.

Reply to
Archimedes' Lever

Ok, I haven't followed the entire silly thread. From my side I've only been proposing that high impedance meters can be a problem, and the solution is using the right tool for the job.

Dave.

Reply to
David L. Jones

No, that's the backhand side of the expression. He doesn't blame his tools because he understands when he makes a mistake it's his. Hackers blame everyone else, and the tools (even if they have the best).

Reply to
krw

Yes, they can be a problem if YOU DON'T UNDERSTAND WHAT YOU'RE DOING. If you know what you're doing you can get the right reading form a high impedance meter just as well as one that has been crippled by the manufacturer. If necessary, you can cripple it yourself, though that is rarely needed.

Reply to
krw