Convert HSpice Diode Model to PSpice?

Mar 28, 2007 4 Replies

Anyone know, or have pointers, on how to convert an HSpice Level=3 diode model to PSpice?



Thanks!



...Jim Thompson



-- | James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC's and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | |

formatting link
| 1962 | America: Land of the Free, Because of the Brave


Run it in HSpice. Note the graphs and use the PSpice model maker!

Kevin Aylward ka@anasoftEXTRACT.co.uk www.anasoft.co.uk SuperSpice

My HSpice expired in the early '90's

I still have the H9001 manual but, like all things HSpice, it's total s*it.

Will HSpice models run on your simulator, or on LTspice?

...Jim Thompson

-- | James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC's and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | |

formatting link
| 1962 | America: Land of the Free, Because of the Brave

I would reckons you can just ignore the non spice3 parameters. Theres aint much in a diode model.

Kevin Aylward ka@anasoftEXTRACT.co.uk www.anasoft.co.uk SuperSpice

"Jim Thompson" wrote in message news: snipped-for-privacy@4ax.com...

I have a more recent version of HSPICE and manuals, but they don't really explain Level 3. Another manual, for a different Spice, explains that Level

3 models bottom and sidewall junction diodes are modeled separately, recombination is modeled at low bias levels, and high-level injection under moderately large signals is modeled.

-- Mike --