Battery Pack temperature sensor (Thermistor)

Sep 05, 2007 22 Replies

The B is not exact. It is supposed to be 3435, not 3375.

Best regards, Spehro Pefhany

"it\'s the network..." "The Journey is the reward" speff@interlog.com Info for manufacturers: http://www.trexon.com Embedded software/hardware/analog Info for designers: http://www.speff.com

Un bel giorno Spehro Pefhany digitò:

B depends on the range for which it's defined. The NTCs that I've listed have a B of 3375 for the range 25-50 °C, and a beta of 3435 for the range

25-85 °C. Just like the Samitec 103AT.
emboliaschizoide.splinder.com

Ah, now that's helpful. Thank you!

Best regards, Spehro Pefhany

"it\'s the network..." "The Journey is the reward" speff@interlog.com Info for manufacturers: http://www.trexon.com Embedded software/hardware/analog Info for designers: http://www.speff.com

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required