increasing number of frequency digits in AC analysis in spice 2G6

I'm trying to increase the number of digits in the _frequency column_ of an ac-analysis like this: .options numdgt=7 unfortunately this does only increase the number of digits in the "voltage (and current) columns" , the frequency column however is unaffected.

e.g.

1.122E-02 -2.153112E-02

in which the first value represents the frequency and the second a voltage Can anyone tell me how to make spice 2g6 to generate more digits for the first value?

hugo

Reply to
hugocoolens
Loading thread data ...

In the .AC analysis specify finer steps.

...Jim Thompson

--
|  James E.Thompson, P.E.                           |    mens     |
|  Analog Innovations, Inc.                         |     et      |
 Click to see the full signature
Reply to
Jim Thompson

I tried this but it doesn't help as Spice just begins to repeat frequency values in stead of refining them e.g. 1.006E+01 -3.601257E+01 1.006E+01 -3.601690E+01 1.007E+01 -3.602124E+01 1.007E+01 -3.602557E+01 1.008E+01 -3.602991E+01 1.008E+01 -3.603424E+01 1.009E+01 -3.603856E+01 1.009E+01 -3.604289E+01

regards, hugo

Reply to
hugocoolens

Maybe it's 2G6. In PSpice, with 101 Points per Decade, I'm getting

*15* place accuracy for Frequency.

...Jim Thompson

--
|  James E.Thompson, P.E.                           |    mens     |
|  Analog Innovations, Inc.                         |     et      |
 Click to see the full signature
Reply to
Jim Thompson

yes, it is 2G6 I am using, it seems hard to believe it is not possible to increase the number of digits in the frequency column. Is this a bug? Or is there a workaround (except using PSpice of course) regards, Hugo b.t.w. Spice 3F _does_ give 7 digits for the frequency

Reply to
hugocoolens