Philips PM3262 Oscope Failure Help needed

I picked up a Philips PM3262 Oscope at my town's recycling center. it looks like it has been well used.

I plugged it in and turned it on. It worked normally for about 2 minutes and then shut down. The ckt breaker on it did not pop. The "ON" light was off. After I let it sit for a while, this repeated.

I don't have schematics and when I took the covers off I did not see anything obviously out of kilter.

Has anyone had this problem and fixed it easily? If so, could you post the fix?

Thanks in advance.

Al

Reply to
Al
Loading thread data ...

Had a similar problem with a Philips PM scope. Turned out to be the high voltage transformer shorted a turn after it warmed up. I rewound the thing...yeah, that was an ordeal. Worked for a few days and shorted out again. mike

--
Return address is VALID!
Bunch-O-Stuff Forsale Here:
http://nm7u.tripod.com/homepage/sale.html
Reply to
mike

Had one of these as a bench 'scope back in the day. Most of the internal voltages come from a switch mode power supply which will fail as you describe at the slightest provocation. Tough to fix without circuit diagrams and you will need a 'scope that works.....

Reply to
Roger_Nickel

From the responses I've gotten, it's best for me to take it back ;-)

Al

Reply to
Al