My 'MUST' solar 3 phase Energy Storage Inverter(12KW, 48VDC) can charge alr ight but is not transferring power to the output (AC ). It shows an error c ode of 80 which says CAN fault in the manual i downloaded. I removed and re
-fix all the communication cables but the problem persist. Will happy with any help on how to go round the problem. Thanks.
Didn't find your answer? Ask the community — no account required.
P
Peter W.
lright but is not transferring power to the output (AC ). It shows an error code of 80 which says CAN fault in the manual i downloaded. I removed and re-fix all the communication cables but the problem persist.
I get two interpretations of an "80" fault code". The first is directly fro m MUST, the second from the International Standard for Inverter Fault Codes :
Communication fault CPU communication fault
1.Restart inverter.
2.If error message still exists, contact the installation contractor or supplier.
< Derating occurred > The power supplied by the inverter was reduced to below the nominal power d ue to high temperature for more than10 minutes. Check ventilation Check heat dissipation
Trusting the first over the second, and expecting that this is a grid-tie d evice, and that connecting to the grid requires good synchronization, which is managed by a CPU - I suspect that it it is not a physical problem (per your re-securing the communication cables), I expect that the Grid-Tie CPU is fried. But, before admitting to that catastrophe, have you checked the ' other end' of the communication cables? In general, it would be useful to k now where you are, the age of the unit, and other niceties. For the purpose s of this reply, I am assuming (always dangerous):
Input Voltage: 48 VDC Output Voltage: 230 VAC x 3; Y; Pure Sine Wave; H/N = 230 VAC
50 - 60 HZ to match utility For the most part, these CPUs are EEPROMs, and if not under warranty, you m ay be able to get a "fix" directly from the supplier at a reasonable cost. Good to have anyway, and probably delivered to you in the form of a memory card.
Peter Wieck Melrose Park, PA
F
fynnashba
lright but is not transferring power to the output (AC ). It shows an error code of 80 which says CAN fault in the manual i downloaded. I removed and re-fix all the communication cables but the problem persist.
Thank you very much Peter. I have done all you suggested its seems the prob lem is software or firmware. i have seen the CD that came with the unit so I will install it and get back on what ever happens. I appreciate your effort.
Join the Discussion
Have something to add? Share your thoughts — no account required.