Can I remove the choke?

I have an older laptop PC. It has a inline transformer. In other words, the transformer is between the wall plug and the PC. The little plug came off where it plugs into the PC. I have some of those plugs, but there is not enough wire between a cord choke, that is right at the end of the cord by the PC. It's molded on the wire so I cant move it.

What would happen if I just remove it and put my plug on without that choke? What are those chokes for anyhow? I can understand them on video cords and so on, but why are they needed on a power cord?

If I can install my plug without the choke, I will, and that will only be for a short time. I bought a new cord on ebay, but I use that computer all the time and dont want to wait till I get the ebay one. After that, the repaired one will only be a backup cord.

Reply to
oldschool
Loading thread data ...

The choke tries to kill EMI coming out of the computer. Cut it off, and buy a snap-on one to go over the finished cable.

Clifford Heath.

Reply to
Clifford Heath

Or cut it off, then demolish the plastic molding that fixes it to the cable (revealing the ferrite core), put that on the cable before you attach the plug, and fix it in the way you like. Suggestion: use two small cable ties around the cable on each side of the core to fix it in place, then put suitable heat shrink tubing around the whole thing for better appearance.

Reply to
Rob

yes, they work fine without. If you want you could also strip the ferrite ring & slip it onto the flex, or slip a different one on.

NT

Reply to
tabbypurr

The choke is to help stop the computer and switching power supplies from sending out signals that can cause reception problems with other receivers.

As far as the computer goes it is not needed at all. Without it any device near by that has a receiver may not work correctly. That can include the wireless mouse and keyboard or wifi modem that is used with the computer you are using. Mostly rare cases, but can hapen. FM radios may not work well that are near by.

Reply to
Ralph Mowery

If you want to restore the functionality of the original "choke" which is a ctually a ferrite bead, you'd need to find the equivalent of the original p art. And it's not like they are marked.

Just cut it off, it'll work fine. Those are placed on there to meet regulat ory requirements. The radiated emissions levels from common equipment are v ery low, and the susceptibility of adjacent equipment is very good. You'll have no issues.

I spent several years running an EMC lab. I had a hand in putting those fer rites on many pieces of equipment, not to solve a real problem, but to get the equipment to comply with regulations. There were a very few cases where the ferrites were installed to solve a susceptibility problem, one that ha ppened at ridiculously high field strengths in every case.

Reply to
Terry Schwartz

Thanks for everyone's help!!!

Reply to
oldschool

Indetails :

In DC annd LF (50/60 Hz), cooke doesn't change anything

In HF it make the impedance od the cale higher so, HF in return is blocked to comply EMC rules.

It is a common mode dual inductance.

It is easy to create one with a suitable toroid and somes turns of the 2 wires in //.