Fried LED 7 seg displays - Help required

Aug 06, 2003 4 Replies

Hi group



Patient - 1 very expensive display unit for a wind turbine regulator .



All the LED displays are damaged - one is blackened ! . I need to replace them all .



The number is UPS5161BH and these are about 15mm high (outside size) and 10mm digit height with decimal point on right hand side , The pins are top and bottom of the display, 5 each AFAIK .



It seems to have taken a near direct strike - I have never seen an LED display this badly damaged before .



Please phone 01481 257551 if you find a supplier or have four of these displays - this is urgent . Thanks !


-Andre


You have a bigger problem than you think. The visible damage is a symptom of invisible damage. Very likely the control electronics is history.

Regards, Boris Mohar Got Knock? - see: Viatrack Printed Circuit Designs http://www3.sympatico.ca/borism/ Aurora, Ontario

Not only history, but modern art as well ! ;-)

I've ordered all new semis - luckily they are all socketed .

Thanks - Andre

--------------------- Sounds like generic 7-segment displays. The only feature you need to ascertain is whether they are common anode or common cathode. Then you need to find out why the driver blew them up so it doesn't do the same thing to the new ones. Check the power supply for shorted regulator.

-Steve

-Steve Walz rstevew@armory.com ftp://ftp.armory.com/pub/user/rstevew Electronics Site!! 1000's of Files and Dirs!! With Schematics Galore!! http://www.armory.com/~rstevew or http://www.armory.com/~rstevew/Public

------------ Be sure and check the voltage and the driver chips!

-Steve

-Steve Walz rstevew@armory.com ftp://ftp.armory.com/pub/user/rstevew Electronics Site!! 1000's of Files and Dirs!! With Schematics Galore!! http://www.armory.com/~rstevew or http://www.armory.com/~rstevew/Public