Legal to sell DC-DC Converter *Kits*?

I found it hilarious when I first came across UL.

I have an article on it I could perhaps post in abse.

Graham

Reply to
Eeyore
Loading thread data ...

out

oad

.

ins

s
,
k

m/electronics/ucurrent/

CUTE BUT IS IT PRACTICAL

I AM PROTEUS

Reply to
proteusiiv

Yes, unlike your multimeter at measuring current accurately in low voltage circuits.

Dave.

Reply to
David L. Jones

How is this shunt better than the shunt in the multimeter?

Reply to
krw

Mine has orders of magnitude lower burden voltage than a multimeter. Almost every multimeter on the market has a high enough burden voltage at high displayed currents (relative to the range) to be a REAL problem the lower your circuit voltage gets. It can even be a big problem with 5V supplies.

Dave.

Reply to
David L. Jones

In article , snipped-for-privacy@gmail.com says...>

You're going to have to explain this one.

Reply to
krw

The current passing through the shunt causes a voltage drop. This only occurs when the multimeter is in-circuit, so inserting the multimeter changes the behaviour of the circuit. If the voltage drop is significant, then the current displayed by the multimeter could bear little or no resemblance to the current in normal operation (without the multimeter present).

Reply to
Nobody

Obviously, since this is what is needed.

Sure (uncertainty, and all that).

So this box becomes a permanent fixture of the DUT? It is never removed, permanently changing the behavior of the DUT? Hardly seems like a reasonable explanation.

Reply to
krw

No problem. Best way is with a cut'n'paste example from next month Silicon Chip article that should explain it:

QUOTE: "Let's look at how the supply voltage can impact your current measurement, or vice-versa as the case may be:

Lets say you want to measure the supply current of a chip or circuit taking

200mA using say a 4000 count meter on the 400mA range. A not uncommon scenario, and one you would think would be pretty easy for any mutlimeter to handle right? - Hold on.

A typical high end "accurate" multimeter will have a "low" 1mV/mA burden voltage (about as low as it gets), so this means the meter will drop 200mV across its shunt resistor at 200mA. This represents an almost tolerable 4% (200mV / 5V * 100) of a 5V supply voltage. This may not be a big deal if your supply voltage is spot on 5V, as your chip will get 4.8V and still be within spec. But what if it's already say 4.8V?, your chip or circuit is now getting 4.6V and may be outside of its operational spec. This already shows the limitation of the current range on a typically mid to high end multimeter. Not to even mention the circuit current can differ when you lower the rail by 0.2V.

Let's now say you need to do the same thing on a modern circuit or chip with say a 1.2V power supply. That same 200mV burden voltage is now a whopping

17% (200mV / 1.2V * 100) of the supply voltage. Your circuit will likely fail to function correctly and this is clearly not acceptable, not to mention inaccurate.

Think this is only a problem with "cheap" meters? Think again. The Fluke

87-V, probably the most popular high-performance meter available has a burden voltage of 1.8mV/mA (which is still pretty good). So the above numbers are even worse - a 360mV drop for a 200mA current.

Sure, you can switch up a current range, using the 10A jack, with its burden voltage of say 10mV/A, giving you a very nice drop of only 2mV. But your display is now showing 0.200 or 0.20 instead of 200.0 - you've just lost a valuable digit or two of resolution. And the higher 10A current range is likely much less accurate than the mA range too!"

/QUOTE

And that's the same with virtually every multimeter on the market, regardless of price.

Some are a LOT worse. Try the above example on a Fluke 77 Series III or a Meterman 37XR for example.

They will drop so much your 1.2V circuit will get ZERO volts. The Fluke

79-III is so bad Fluke decided to remove the 400mA range entirely.

And that's of course not even mentioning that the current accuracy on almost all meters is a lot worse than the basic DC voltage accuracy. Try 5 times worse for an average.

So my uCurrent provides a much lower burden voltage and uses the more accurate voltage range to measure current. So it solves two rather annoying prolems in one hit.

Nothing tricky about it at all, it's just that no one has bothered to do it before as a multimeter add-on (that I am aware of). But it's carefully considered and done all the time in in-circuit current shunts.

I suspect the article will be a real eye-opener for some people.

Dave.

Reply to
David L. Jones

Correct, and the drop gets higher the closer you get to full-scale on your current range. Virtually every meter on the market will have between 1mV/mA and 10mV/mA burden voltage for the mA ranges, so do the math for the 200mA range and then ask if your circuit can handle (or be affected by) that drop. Similar but often not as bad for the uA ranges.

Dave.

Reply to
David L. Jones

What'd be useful is a momentary-action pushbutton that applies a dead short, so while your clip leads are in circuit and you're testing it, you can hit the button to see if the behaviour changes. That way you know if the meter matters.

Clifford Heath.

Reply to
Clifford Heath

Nice idea, but it's not just the circuit behaviour that matters it's also the current accuracy of what you are measuring. Your circuit might still be within spec and fully functional, but when you put that meter in series it can change the actual circuit current. Makes an already inaccurate current range even less accurate. If you are not concerned with high accuracy then a regular multimeter will usually suffice of course.

Dave.

Reply to
David L. Jones

Nice idea, but it's not just the circuit behaviour that matters it's also the current accuracy of what you are measuring. Your circuit might still be within spec and fully functional, but when you put that meter in series it can change the actual circuit current. Makes an already inaccurate current range even less accurate. If you are not concerned with high accuracy then a regular multimeter will usually suffice of course.

Dave.

Reply to
David L. Jones

Also, don't ignore the volt drop in your test leads - unless you abandon your standard leads for something considerably thicker - and shorter. You will also have to replace the 4mm input sockets on your meter with adequately rated screw terminals.

Don't forget the power dissipated in the shunt either. If you're measuring

20A and your volt drop is 200mV, your shunt has to dissipate 4W. This is Ok with a properly designed external shunt but not if you're going to stick it inside the average multimeter case.
Reply to
Stuart

[snip]

Maybe you should elaborate on exactly what you want explaining. I took it as "why does it matter that it has orders of magnitude lower burden voltage than a multimeter?". If that wasn't what you were asking, then my reply is of no use to you.

Reply to
Nobody

It appears you don't know the UL/CSA safety specs. Without those, you are truly lost. And you won't learn them in a day or two. Do not sell anything with any voltages greater than 42V. Design to UL/CSA specs, advertise it thusly and be certain you actually did that correctly. Many labs around the country would do a test suite for you for a reasonable price, and then you could use those in your adverts too. Note that many cities, counties and town around the country won't allow a product to be sold unless the safety approval is in place, though. All of Ca, NYC, Chgo, DC and FL are a few of them. Also be certain that every component has a UL or CSA listing also. It doesn't guarantee you'll USE them correctly, but if you do, at least the components are listed.

Burn down my house and yes, you have a guaranteed law suit on your hands. But then, I would never purchase anything that was not UL approved, including kits. It's difficult to get approvals on kits, too. Lot of hoops to jump thru.

Go talk to UL; they will talk to you and give you some good info.

Reply to
Twayne

You're missing the point: What is its source? The output itself is almost irrelevant. Don't do this; you are not prepared to handle it.

Reply to
Twayne

It appears that you are nothing more than a mouthy little bitch.

Reply to
Mr.Eko

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.