Embedded Programming

16390 Threads Posts
to

non-necessity of northbridges

what functions do northbridges provide? i realize theres a lot of I/ O breakout, but if you dont need the I/O, is there...
2 comments posted 19yrs
posted by rektide
2 comments posted 19yrs posted by rektide

need Tips on increasing performance of an I2C driver

Hi, Can someone share some tips on how to increase the performance of an I2C driver code . My driver code do an EEPROM a...
3 comments posted 19yrs
posted by Gaurav.Saikia
3 comments posted 19yrs posted by Gaurav.Saikia

AL422B

- Is AL422B still in production? - As for Read Operations the datasheet notices: "When the new data is read, the read a...
1 comments posted 19yrs
posted by emb
1 comments posted 19yrs posted by emb

VIA EPIA series SBC - any views?

Has anyone used the EPIA series board from VIA? http://www.via.com.tw/en/products/mainboards/ Specifically the EK model...
5 comments posted 19yrs
posted by aribloch
5 comments posted 19yrs posted by aribloch

verilog HDL problem

what is the error in the following code. in it the main module is "test". in that module's "always" block another modul...
1 comments posted 19yrs
posted by nasif4003
1 comments posted 19yrs posted by nasif4003

von Neumann like microcontroller

Is there any microcontroller that allows one to map RAM into the program address space? In other words, act like a von N...
5 comments posted 19yrs
posted by nospam
5 comments posted 19yrs posted by nospam

Board data wrong on Xilinx ML403 board

Anyone, I am trying to get linux to run on a Xlinix ML403 board. I am using an elf file to boot from. I'm using 'xmd' f...
0 comments posted 19yrs
posted by gseegmiller
0 comments posted 19yrs posted by gseegmiller

A simple USB question

Hi! I have an AT91SAM7S-EK kit with an AT91SAM7S256 microcontroller. This microcontroller supports 4 Endpoints - EP0, E...
9 comments posted 19yrs
posted by vasu.sharma
9 comments posted 19yrs posted by vasu.sharma

Best solution for CAN monitor?

Hi, we are looking for a simple and robust solution for monitoring traffic on a CAN bus and for sending out CAN message...
5 comments posted 19yrs
posted by baur
5 comments posted 19yrs posted by baur

Atmel AVR TWI baud rate register

The Atmel application note about using the TWI (AVR315 dated 09/04) states that the TWBR should be set to a minimum of...
0 comments posted 19yrs
posted by spamj_baraclough
0 comments posted 19yrs posted by spamj_baraclough

Green Hills ARM Compiler has no #print directive?

Green Hills users, We have recently been converting from ARC processor to ARM processor. The ARC compiler allows inclus...
2 comments posted 19yrs
posted by nospam
2 comments posted 19yrs posted by nospam

GUI interface to an embedded system

Hi: I'm developing am embedded system with Ethernet, USB and Serial ports. I want to provide a GUI interface which the...
6 comments posted 19yrs
posted by gfm5050
6 comments posted 19yrs posted by gfm5050