Hi,



I'm supposed to be moving our boards from the PIC18F458 to the PIC18F4580, which has the ECAN on it. At the moment, I'm not having a great deal of joy... Has anyone else managed a migration from an Fxx8 to an Fxx80 pic?



cheers, Rich.



rich walker | Shadow Robot Company | rw@shadow.org.uk technical director 251 Liverpool Road | need a Hand? London N1 1LX | +UK 20 7700 2487 www.shadow.org.uk/products/newhand.shtml

In article , Rich Walker writes

If you use legacy mode 0 on the 4580 then there's very little you should need to do to continue using the 458 code as is. You will need to check the errata for each part though - I seem to recall one or two minor tweaks needed to accommodate the errata differences between a similar pair of chips (e.g. there's an unintended inversion of SEG2PHTS on some chips).