IOW Can the cap be left there permanently to allow a FM intercom to communicate across the panel?
- posted
15 years ago
IOW Can the cap be left there permanently to allow a FM intercom to communicate across the panel?
noone has said this is a good idea.
run/start capacitors typically have motor windings connected in series with them which limit the damage if the capacitor shorts out.
For connection across the power lines a "class X2" capacitor is indicated.
Also filter X capacitors are designed to pass radio frequency, run (or start) capacitors may not be. thus you may see adequate performance with a much smaller capacitor that the motor caps.
larger X2 caps can be had in the form of PFC capacitors.