IOW Can the cap be left there permanently to allow a FM intercom to communicate across the panel?
What would happen if a run start capacitor is installed across the 220 VAC?
Apr 01, 2009
1 Replies
noone has said this is a good idea.
run/start capacitors typically have motor windings connected in series with them which limit the damage if the capacitor shorts out.
For connection across the power lines a "class X2" capacitor is indicated.
formatting link
formatting link
Also filter X capacitors are designed to pass radio frequency, run (or start) capacitors may not be. thus you may see adequate performance with a much smaller capacitor that the motor caps.
larger X2 caps can be had in the form of PFC capacitors.