Need some advice on powering a bank of fluorescent lights. My controller uses a PIC 16F876 to a 2803 Darlington array to power 10A
240V relays one of which powers the 240v AC light bank. There are about 9 lights in the bank (my garage), ranging from 40W to 70W, each with their own starter, amounting to about 450W operating power. Other relays power other light banks lesser in number and operating power, with no problem.
The problem symptom is a resetting PIC when the relay is fired. The same happens if the lights are powered by the original light switch. The problem cause I believe is inductive spikes during the lights power-up cycle. I have scanned the groups and can't see this specific problem being discussed. What is discussed has led me to try varistors across the load and across the relay contacts both at the relay. I think, by doing that, I am preventing the spikes from being inducted through the relay into the DC power lines, spiking the PIC. However, I have read that this might not prove a good solution if spiking is regular. In any case, it doesn't work, and in fact seems to cause the problem to occur more consistently now.
I haven't yet attempted an RC snubber - not totally convinced on what I would be achieving with that and would prefer some specific advice on the problem first.
If you can help, I would be most grateful.
Regards,