Phase locked loop question

Could some electronics guru please help me ? Suppose I have phase locked loop in "locked in" state. Now suppose that I wish to use the reference signal for some further processing ? To be more precise, what signal has to be monitored on the phase locked loop, so that I know that the "locked in" state has been achieved, keeping in mind that the loop filter, generates an average value of the input signal, on successful loc in. Nay hints, suggestions would be of immense value

- thanks in advance for your help.

Reply to
Daku
Loading thread data ...

It depends on the phase detector. What it is will define how to go about adding a lock detector.

If it's an IC specifically for the task, the manufacturer's datasheet or application note is likely going to show a lock detector.

Michael

Reply to
Michael Black

It depends on more than just the phase detector! Lock detectors generally work -- one way or another -- by monitoring the error signal and deciding when it is quiet enough to declare lock.

If the input signal is noisy, either with additive noise or with timing jitter, the noise signal can confound a lock detector to never declaring lock -- conversely, if you try to design the lock detector to work in the presence of the noise, you open the door wider to falsely detecting lock.

If the input signal is nice and quiet, then the lock detector becomes easy -- see any 4046 PLL data sheet for a nice digital implementation.

--
Tim Wescott
Control system and signal processing consulting
 Click to see the full signature
Reply to
Tim Wescott

In this case, it could be argued that lock has never been established.

Maybe it is. It could be argued that the lock detector defines "lock". ;-)

Yes, the lock detection circuits does depend on the phase comparator, as Mr. Black said above.

Reply to
krw

Could be, but then it could be that you'd just be playing semantic games.

Saying "A is A when my 'A measuring tool' says it is" is a test of your customer's credulity, not your tool. It means that the lock detector is never wrong, even when, looking at the reference signal, the PLL output, and the lock detector output gives you an obviously ridiculous relation.

If you define "lock" as "the phase and frequency of your PLL are currently bang on the mark" then suddenly you can have an independent test that you can use to check the veracity of your lock detector -- and everything I said above is valid.

--
Tim Wescott
Control system and signal processing consulting
 Click to see the full signature
Reply to
Tim Wescott

It has to be one or the other.

No, you have an specification that is impossible to meet.

Reply to
krw

A more reliable way is to use a second phase detector but shift its LO input 90 degrees, usually digitally. So when the main detector output nulls, the output of the second PD peaks. That state is observable.

Another way: if the loop includes an integrator, the integrator may rail when the loop is unlocked; that's easy to detect.

John

Reply to
John Larkin