amperage rating for 30 awg kynar

Oct 18, 2007 5 Replies

i google'd this and found 3 Amps ? is that correct ? did i mis-understand ?



That just seems high considering the size of wire , i was planning to connect some IC pins to PCB with this wire where the voltage levels are 32v and 5v and the currents are 40 mA and



10 mA .

Thanks for any useful help, robb


3 amps is correct. You need to derate if bundled or enclosed where where there would be excess heat.

Tom

--- The 3A is specified so that with that charge flowing in the wire the temperature of the wire won't rise above some maximum value at some ambient temperature, say 70C with a 30C ambient.

Since 30AWG wire has a resistance of about 0.1 ohms per foot at 30C,

with 40mA in the wire it'll dissipate:

P = I²R = 0.04A² * 0.1R = 1.6E-4W = 160 microwatts per foot

Likewise, at 10mA you'll be dissipating 10 microwatts per foot, so in either case you'll have absolutely noting to worry about.

-- JF

The table I googled shows #30 at .86A for chassis wiring. That sounds a lot more plausible to me.

Hope This Helps! Rich

30C,

foot

so

Thanks John,Tom,Rich, for your time and help. robb

Here is a link using a chart from Alpha:

formatting link

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required