Triac or relay to switch AC power?

Feb 01, 2005 10 Replies

Triac or relay to switch AC power?



I want to use a controller to switch for an hour the AC power of a light bulb. Should I use a triac or a relay? Besides the circuit needed to drive the triac or the relay, what are the parameters I should be aware of to choose between the triac and relay? In both cases, the controller has to keep sending the signal for an hour; The circuit around the controller will use current for an hour and I am concerned about this consumption and want to keep this consumption as low as possible.



Use triac then. The current will be no more than an LED.

Get a wind-up timer and be done with it. Fits right into the box in the wall and does everything you asked for. mike

Return address is VALID. Wanted, PCMCIA SCSI Card for HP m820 CDRW. FS 500MHz Tek DSOscilloscope TDS540 Make Offer http://nm7u.tripod.com/homepage/te.html Wanted, 12.1" LCD for Gateway Solo 5300. Samsung LT121SU-121 Bunch of stuff For Sale and Wanted at the link below. http://www.geocities.com/SiliconValley/Monitor/4710/

Consider a solid state relay. Easy hookup. I use a 25 amp SSR and PIC-based timer to cycle a 1500 watt space heater that used to be inop. because its thermostat had died. Ten years old last fall and still running fine.

How do you want to start and stop the timer?

The lowest power usage I can think of is by using a bi-stable relay. It only uses a bit of current when switching on or when switching off.

Joop

The simplest way to achieve success without knowing much about electronics is to use an AC relay actuated by a your controller through a TRIAC. The sizing of the relay driving an incandescent load has to be adjusted downward from the maximum current rating of the relay to something like 30-40% because of the cold filament surge and possible filament failure scenarios. So if your bulb is say 300W @ 240VAC, then I=W/V=300/240=1.25A -use a relay with contacts rated at 5A @240VAC and

240VAC coil. Then use a 600V TRIAC with 1A or more current rating to drive the coil like so:

View in a fixed-width font such as Courier.

Maybe the simplest in your case would be to use a DPDT AC relay configured as self-latching, and then use timer to pulse two logic level mini-relays ( one with normally close,nc, the other with normally open ,no, contacts) with AC rated contacts to initiate ON/OFF operation. The quiescent overhead from the controller is now zero. View in a fixed-width font such as Courier.

. . DPDT AC PWR RELAY . +--------------+ . | / | . LINE -----------|--+-----o o---|----------------->

. | | | TO LAMP . | K|| | . | K|| | +---->

. | K|| | | . | K|| | | . | K|| | | . | | | | . | +--------+ | | . | | | | | . | o | | | . | / | | | . | o | | | . | | | | | . +--------------+ | . | | | . | | | . o o | . nc |

Relay DPDT Self-Latching connection I want to use VCC=5V to drive a 120AC line. How would you connect the DPDT relay as self-latching?

VCC----+ | | | | | | | | +-----------------------------------------+ | | NC COM NO NC COM NO | | K|| | | K|| | | K|| | | K|| | | K|| | | K|| | | K|| | | | | +-----------------------------------------+ | | Ground----+

A relay that "self-latches" is not a latching relay. Latching relays maintain their last state without power applied to the coils. Because you are concerned about power consumption in the timer, you either power the relay off the AC line or use a true latching relay. It will be cheaper for you to use surplus standard 5VDC coil relays that you

*pulse*- like these
formatting link
to drive a standard AC-line relay like this:
formatting link

formatting link

formatting link

From Fred's point of view, I think VCC should be replaced by the LINE with a connection like this:

+------------------------------+----------+ | N.C. = 'off' | | LINE----+---o/ o-------+---o__o----+ | | N.O. = 'on' | | | | +--- load | | | | | | | +-----------------------------------------+ | | NC COM NO NC COM NO | | K|| | | K|| | | K|| | | K|| | | K|| | | K|| | | K|| | | | | +-----------------------------------------+ | | Ground----+

This way, the consumption is not from the controller/timer "board" because the board drives the two small relays with pulses, but there is still consumption for this "AC" relay from the LINE while the load is powered. To take the overall consumption at a minimum, a latching relay should be used? Or how much current, voltage or power this AC relay takes when there is current in its coil?

********************************************* 120 VAC DPDT 10 AMP RELAY Kest # KRLY-2120. 120 Vac, 5000 ohm coil. D.P.D.T. 10 Amp contacts. KH "Ice cube" style,clear polycarbonate case. 1.1" x 0.83" x 1.37" high. Solder or 0.187" qc or solder terminals. CAT# RLY-2120 **********************************************