You must have crappy hardware.
You must have crappy hardware.
switches
understand
the
so
it
how
Then the hierarchical thing doesn't seem to be much different than just doing it flat.
John
If I have anything to do with it... They already have the PCs, but use them to view PDFs.
I think I finally got them to understand that engineering really needs prices. Sometime in the future they're going to dump the purchasing database into the parts database once a month. It's a start. Quantity?
Next issue: how do you deal with multiple SKUs built off the same schematics? They want us to manually edit the schematics for service. I'm trying to convince them that they really don't want to do that. I certainly don't want to be held responsible for multiple versions of the same data.
switches
understand
the
drawn so
it
how
If the most important thing in life is the cost of printer paper, you may have a point. OTOH, hierarchies are easier to understand, simulate, and reuse; sorta the point of schematics.
Or perhaps not knowing that there were things that required setting up.
Few Linux apps crash. That doesn't magically make it a robust app, however. Wallet or not. Time has a price as well, and mine ain't cheap.
switches
understand
to
the
drawn so
if it
the
how
Somehow I don't have trouble understanding 16 sheets that are labeled CHANNEL 0 through CHANNEL 15, each with all the reference designators and connector pins in plain view.
John
Mine is all updated, and has NEVER crashed.
When you attempt to print a large pdf, you should locally spool the print job first. If you do not know how to set your printer/computer up to spool properly, you deserve to have crashes until someone guides you through the process.
Operator error... again.
Don't know for sure. What release are you on? Unfortunately, I only have 10.3 to work with, and I think they added diff pair support around 16.0...
Charlie
I'm using Capture 15.7, but the "diff pair" support is pretty much just another property (though is only editable in flat nets view). We're then using Allegro 16.0 for the layout. It does reuse and diff pairs, or so I'm told.
switches
understand
to
up the
drawn so
if it
the
That's how
major
block
And nothing would change if those sixteen sheets were instances of a hierarchical block, except you'd have another higher level block that would show their interconnect. IOW, more information.
I'm puzzled. What IS "diff pair" support?
...Jim Thompson
Hehehehe...
It essentially is a way to mark the wires as a pair so the router can use, and DRC check, the appropriate wiring rules.
Hi Jim, Differential pairs, used for sending digital signals on PCBs. They required the two traces to be matched in impedance and delay, and usually they are routed adjacent to each other. Allegro has support for routing in this mode, and Concept deals with it pretty easily. On the schematics, it is just a property of the traces to let the layouter know they need to be kept together.
Charlie
Dell, Samsung, another Dell, plus a ruggedized laptop. Not exactly bottom of the barrel ;-)
Umm, it runs under Windows XP. It is a robust app.
Then how come all the other software doesn't have such problems? Looks like they did something right, doesn't it?
Quantity on hand should be in there as well. So that a rookie doesn't design in the uA741 that purchasing still has to occasionally buy for the old design that uncle Leroy did in the 70's.
Old rule: When only one part on the circuit board is changed in value it is another assembly and must get another assy number. No ifs, buts or whens.
I thought Eagle was a Linux app.
Also, there is more to being robust than whether or not it crashes. Under ANY OS.
Eagle is not on the list.
Have something to add? Share your thoughts — no account required.