Current measuring resistor calibration

Hi, I need to measure current in the range of 1mA to 10A. The precision I need is 0.1% of the current that I'm measuring i.e for

10A current i need 10mA resolution for 1A I need 1mA resolution and so forth. Potential across resistors are fed to an Opamp that has offset and gain trimming networks. The current is changing within the range limits and I need to measure current continuously and send the value to computer. I have built a prototype but I have some problems that I hope you can help.

Because the range is too broad to be measured accurately with only one resistor, I have used these resistors:

-----------------------------------

0.1 Ohm -> 1A to 10A 1 Ohm -> 100mA to 1A 10 Ohm -> 1mA to 100mA

-----------------------------------

Now Problems that I have :

1- When I try to calibrate each resistor's gain an offset it causes a gap with other resistors e.g. when current is increasing from 50mA to 200mA and I have to change current measurement resistor from 10 Ohm to 1 Ohm at point of change I read two different currents for 100mA i.e. 10 Ohm resistor reads it 100mA but 1 Ohm resistor reads it 115mA.

2- When current is high (>1A), current measurement resistor becomes hot and after a while current that it reads change e.g. first it reads 2.16A and after 10 minutes, it reads the same current 2.65A.

3- If I want to mass produce this, is it an easier way to calibrate offset and gain of each resistor instead of manually change trim networks of Opamp?

Thanks in Advance.

Reply to
Petkovic
Loading thread data ...

Actually, you could do it with just one resistor assuming that the current is DC. With a chopper op-amp and careful design, you can get down to a micro volt. You have to beware of the metals involved.

Look very carefully at how you have things wired. It could be that the wiring resistance is getting into your measurement.

I assume you didn't let the drop in the switches get into it.

Check the tempco first. Look at the metals you have in the design to see how many little thermocouples you have made. Look at you op-amps last but don't forget to check.

You can use "electronic pots". These are sort of like DACs with EEPROMs built in.

Reply to
MooseFET

--
The right way is to start with resistors/shunts which have a temperature
coefficient of resistance which will allow you the precision you require
over the temperature range which they will experience.

JF
Reply to
John Fields

The first resistor dissipates 10 watts max, and the next one dissipates 1 watt. They'll get hot, and the heat will change their values and generate thermoelectric potentials. Both will need 4-wire connections to avoid copper errors, especially the first one.

Use lower-value 4-wire shunts to keep the errors down, and low-drift diffamps with lots of gain. 10 to 50 mV max drop is reasonable. Do the zero and span calibrations in the computer.

One good trick is to make provisions for shorting the diffamp input occasionally and auto-zeroing in software. Then you can tolerate a cheaper, driftier diffamp. Software is free in production.

As noted elsewhere, when you switch resistors, make sure the resistance of the switch contacts isn't part of the measurement resistance. In other words, switch all 4 wires to each shunt.

John

Reply to
John Larkin

p.

The first problem might be the opamp DC offset. The second is Joule heating (V*I) and TC of resistor. Drop the value of the resistors, or heatsink them, or both.

"If I want to mass produce this,..."

Good low TC, low value resistors are expensive.

George H.

Reply to
George Herold

lp.

Yeah, that about nails it! Certainly four leads, And I love the shorting trick. Thanks,

George H.

Reply to
George Herold

----------------------------------------------------------------------- I need 0.1uV resolution if I want to measure 1mA with 0.1 Ohm Resistor with 0.1% accuracy. I never could measure lower than 10uV in practice and that only happens if I use every trick that I know. for me 100uV sounds more practical. So if you excuse me I can't do this unless you teach me practically how.

-----------------------------------------------------------------------

--------------------------------------------------------------------------- I have used very wide tracks to ensure there is no IR drops in tracks and also in switches.

but even in lower currents this problem exists. I mean 100mA is not much current for a short(a few Cm) 200 mil track. It should not cause this problem.

---------------------------------------------------------------------------

---------------------------------------------------------------------------- But how to calibrate these digipots? calibration takes a lot of time and I hoped to somehow do it automatically.

----------------------------------------------------------------------------

Reply to
Petkovic

------------------------------------------------------------------------------ Do you think it is possible to produce a board that can produce very accurate currents for this purpose ? I mean how can I make sure that my reference current is let's say exactly 100mA. I mean (100.0mA). Is there an alternative to check it with a very accurate galvanometer? I can produce very accurate voltages using high precision reference ICs but what about current?

------------------------------------------------------------------------------

Reply to
Petkovic

Surface-mount 4-wire low-tc shunts are affordable. IRC, Vishay, KOA, Isotek, Digikey. They are usually stamped out of manganin... production cost must be pennies each.

We punch or photoetch our own current shunts out of sheet manganin, using top-secret shapes to minimize thermals, mag field pickup, and eddy current errors. Typically in the 15 milliohm ballpark.

You can make a pretty good shunt out of a short piece of manganin wire soldered between two pcb thru-holes, with careful 4-wire connections to the pads. Manganin is just a little tricky to solder.

John

Reply to
John Larkin

Sure, depending on what exactly is your purpose. That's not clearly defined here.

Fluke makes bench DVMs that are very accurate on current, like 0.02% to 10 amps. Use one of them as a tracable cal thing.

John

Reply to
John Larkin

-------------------------------------------------------------------------- John, My purpose is to automatically calibrate those current measurement resistors but for that I need to either know the very exact value of each resistor or pass a known(reference) current through them and measure their voltages. Yes there are accurate measuring instruments but problem is they also have to be calibrated. If I remember correctly Fluke guarantees its calibration for just 2 years. Is it possible to produce a reference current without such instruments?

--------------------------------------------------------------------------

Reply to
Petkovic

Hi Petkovic

Take a look at this chip:

formatting link

It looks like this can measure to a high dynamic range due to the low input offset voltages of the (chopper stabilised) op amps. DO NOT buy one without the current sense resistor soldered to it. Soldering the resistor to the board will present problems with the Siebeck effect (thermocouple junctions). If you can buy a module (resistor and ASIC) it will save you lots of production problems.

--
Bill Naylor
www.electronworks.co.uk
Electronic Kits for Education and Fun
Reply to
Electronworks.co.uk

help.

a
1
t
6A

Cool I've only used manganin as heater wire. Not sure the gauge but about 12 ohms per foot. You can get this in thin sheets? I don't remember any problems soldering to the wire. But I was only making heaters, not sensors.

George H.

Reply to
George Herold

[Larkin]

--- I don't mean to be unkind, but you don't seem to have grasped the fundamental fact that if the resistance of your "reference" resistor(s) changes when current through them changes, then you are lost.

Consider: (View in Courier)

+--[Vin]--[Rs]-+ | | [R1] [R2] | | +-----[RL]-----+ | | +-----[VL]-----+

Where Vin is the voltage source feeding the circuit, Rs is its source resistance, R1 and R2 are the resistances of the wires connecting Vin to the load, RL is the load resistance, and VL is the voltage appearing across the load,

then if the resistance of RL changes (because of its temperature or voltage coefficient of resistance, or both, or whatever) when Vin, Rs, R1, and R2 are perfectly stable, VL will also change and won't truly reflect the current in RL.

---

--- Yes, of course:

formatting link

But once you build it what are you going to use to make sure it's working properly?

JF

Reply to
John Fields

There are other voltage reference sources - buried zener voltage references can do better than band-gap parts

formatting link

while Analog Devices offer low voltage reference sources based on FETs.

formatting link
uct.html

Standards laboratories use quantum standards to do rather better

formatting link

-- Bill Sloman, Nijmegen

Reply to
Bill Sloman

I went on to answer the other questions because it is hard to do. I was only pointing out it was not actually impossible. Switching resistors is going to be a lot easier.

You need to run the connections directly to the resistors. This matters the most at the high current end where the resistor is small. You also want to make sure you aren't making thermocouples.

Temperature gradients along the copper make voltage gradients. (This is the real way a thermocouple works). Even at 100mA you are making some heat in the sense resistor.

2- When current is high (>1A), current measurement resistor becomes hot

If you have something that needs adjusting, it takes time to adjust it. Even if you make a computer do the work, it will take some time. It is better to try to design the need out.

Reply to
MooseFET

or

so

t
e

n help.

ne

et

----

h

----=AD>> 2- When current is high (>1A), current measurement resistor becom= es hot

.16A

to

ps

----=AD-

ally.

A micro can assist resistor switching and calibrate linear output. It can also monitor temperature changes for compensations. In productions, you can build lookup tables while calibrating and programming the micro. The so called "ASIC" are probably pre- programmed micro.

Reply to
linnix

------------------------------------------------------------------------------

If you want to be legit, anything that you sell as electrically accurate has to be tracable to a recognized standard, like NIST (in the USA) or equivalent. A Fluke that is in cal is tracable; after the cal interval has expired, it's not.

You can also buy lab standard resistors - very expensive - but they need to be periodically certified, too.

No instrument can calibrate itself, at least unless it relies on some fundamental quantum measurement. A primary-standard current source would cost as much as a thousand Flukes.

Why not buy a Fluke and have it cal'd every two years? Use that to calibrate whatever it is that you're making.

Since I don't know what you're trying to do, that's all I can say.

John

Reply to
John Larkin

You can buy sheet manganin, but not in small quantities. We use some special solder that works better than the standard stuff. We anneal the shunts before we solder them down, which tarnishes them a bit and makes them harder to solder; a brief dunk in dilute HCl shines them back up.

If you stress manganin, it degrades the tc and stability slightly. Annealing after punching/rolling/bending (bake for 24 hours at, say,

120C) fixes that.

John

Reply to
John Larkin

------------------------------------------------------------------------ John Fields, The most usual way of measuring currents is to use a resistor as a current to voltage converter. Yes all resistors have TC,... but this is another issue. For most precise measurements one should uses a resistor with lowest possible TC. what you mentioned is a general issue and not addresses my specific problem. Yes TC is important and you can suppose I make all my effort to lower that effect as mush as I can.

I think I was not clear enough in previous post so I say it again.

I want to calibrate current measuring resistors -> From calibrate I mean to know exactly what voltage a specific current produces across that resistor. If I know this coefficient I can convert the measured voltage to a valid current value in computer and hopefully then there is no gap when I change from one resistor to another. what I said in previous post was that I have two different ways. I said

EITHER:

1- I should learn the exact value of the resistor-> if I know that then I can calculate a valid value for current : V/R.

OR:

2- I should produce a REFERENCE CURRENT not a reference voltage If a reference current passes through a resistor tht I don't know its exact value then I measure voltage and can find the exact value of R (V/I) and from exact value or R I can have a valid current value(See #1).

------------------------------------------------------------------------

------------------------------------------------------------------------- I should produce a ***REFERENCE CURRENT*** not a reference voltage. I explicitly mentioned there are many voltage reference ICs. what I want is either to measure the very exact value of a resistor or produce a

***REFERENCE CURRENT***. And please note that reference currents that I need are 100mA , 1A, 10A not a few milliamp where there are some reference current ICs for them.

-------------------------------------------------------------------------

Reply to