on 19/02/2011, Tabby supposed :r
>
> > > >> I'm looking to source a cheap 240v 30watt mains inverter, to enable me
> >> to vary the speed of a peristaltic pump, if any one comes across one o=
>> happens to have one surplus to requirements.
>
> > You're not giving nearly enough info here.
>
> Which information do you think it lacks?
Now you've told us its a synchoronous motor, and I'm going to guess a
240v motor. The Range of 6 to 0.2 means a min drive frequency of
1.7Hz, and I cant see any 50Hz motor coping with that without significant complication. I think the only answer that will avoid a good bit of work is forget it, and just use a timed on period at 50Hz, or if you're prepared to reduce voltage to 80-100v you could go down to a fixed 17Hz using triacs to invert every 3rd halfcycle.
Surely there are other options too, but you either need the skills to design & construct a non-trivial circuit, or to buy it ready made. Is changing the gearing instead an option?
NT