Margaret Elaine Heafield Hamilton died

Oct 08, 2026 Last reply: 3 weeks ago 94 Replies

There are lots of ways of dealing with skin effect - litz wire is just one of many.

The large gap is presumably between currently deployed power supplies which happen to work, and the universe of possible power supplies which wouldn't work as well (if at all).

Are you saying that you'd use one 500KHz switching power supply transformer where you'd have used one 60Hz power transformer?

The former can be a lot more compact than the latter, and you take advantage of that fact by putting the 500kHz power supplies a lot closer to the devices they were driving - letting you push the DC current further along the 800V DC bus before turning it into the higher current that target devices need. That higher current needs thick copper leads, but with a 500 kHz transformer you can keep them short.

That will save some copper, but it's not a dramatic saving.

We're talking of copper volume in the power supply, not of the length of the condoctors needed to reach the load. There is not the shadow of a doubt that the copper volume in a modern high-frequency switching power supply *is* dramatically less compared to a classic mains frequency supply of the same power.

Jeroen Belleman

formatting link

800 watts, planar windings, hardly any copper, about a cubic inch, surface mount.

Compare that to an 800 watt 60-hz transformer, Bill.

And those Coilcraft planars have hardly any leakage inductance. They will transmit nanosecond pulses.

John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics

I was talking about the volume of copper tied up in supplying the same amount of power, not the volume in a particular transformer.

That's going to be spread across more transformers. Each transformer will be smaller, but there are going to be more of them, in lots of separate switching power supplies.

No copper that you can see. Planar winding do tend to get plated up quite heavily to provide windings with a decent fill factor.

You need to talk to specialist printed circuit shops to get that kind of weight of copper on a printed circuit board.

Why should I? The point I was making was that the iron content does go right down, but an appreciable copper content is unavoidable.

Leakage inductance hasn't got much bearing on the capacity of a transformer to pass fast pulses.

It reflects the flux that doesn't couple the two windings.

It's only frequency dependent to the extent that parallel capacitance diverts high frequency current from flowing through the primary winding and generating the rapidly changing flux that can induce high frequency current in the secondary.

You don't seem to have mastered the transformer equations.

Yikes.

You don't seem to build things with transformers.

It's not been a major element of my career, but I have done from time to time. I've now just applied for an Australian provisonal patent on a new way of making a non-progressively wound toroidal inductor. The problem is discussed in Rayner and Kibbles "Coaxial AC Bridge" ISBN

0-85274-389-0 from 1983, and figure 4_18 on page 103 almost gets the right answer, but - as it says in the text - the antiprogression turn sketched doesn't follow the mean path of the toroid.

If you split the toroidal core into two toroidal half cores and put the antiprogression turn between them, you can put it in the right place, and that's the idea I'm patenting.

Anybody who wants a license can chip in on the cost of turning the provisional patent into a real patent,

The only people likely to be interested are people who use pairs of non-progressively wound inductors to do non-contact fluid conductivity measurements on liquids. If you drop a stacked pair into the liquid, and excited one of them, the current it induces in the fluid will go around both sets of cores and excite a voltage in the second toroid.

It's a very neat scheme, but the only project I worked on that could have used it didn't have room for the toroids.

You kick-started the process here a couple of months ago by claiming toroidal inductors had to have a turn in the plane of the toroid, and thus an external magnetic field.

People cancel that field by making a winding or a wire circle back to the start. Rogowski coils do that, and it gives them the advantage that one can install a flexible R-coil on an existing conductor in-place.

formatting link
A single toroid should work as a conductive liquid sensor. The liquid will form a shorted turn.

We make capacitive liquid level signal conditioners and simulators.

formatting link
I proposed doing a system of capacitive liquid helium level sensors, but the potential user thought it would be impossible. Er is about

1.05. The hot-wire level sensors are awful.

John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics

And they always have. The patentable advantage of my scheme is that it lets you route the wire back along a particular path, without significantly increasing the parallel capacitance of the winding.

If the liquid were conductive enough. My friend in Scotland worked out a way of using a single coil to do that but it needed a fairly conductive liquid.

It's going to be a small capacitance difference, but capacitance bridges built around ratio transformers can be remarkably sensitive and stable.

Rayner and Kibble's "Coaxial AC Bridge" ISBN 0-85274-389-0 from 1983 is a full bottle on the subject.

Your potential user doesn't seem to have been all that well-informed. Get them a copy of Rayner and Kibble and they may come around.

For added extra credit, try to sell them a Thompson-Lampard cross-capacitor as level sensor. It only gives you 1.954pF per metre in vaccum (2.0517pF/metre in liquid helium) but ratio transformers let you balance that kind of bridge to parts per million.

It you wound the ratio transformer with super-conducting wire and sank in the liquid helium you could get even cuter.

It was a National Lab with a gigabuck to spend. I proposed a simple oscillator to measure the capacitance change.

They wound up using the usual hot-wire liquid helium sensor, which we supplied the electronics for. And a lot of other stuff.

John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics

It's not a sensible way to do it. Capacitance bridges can be much more precise.

Rayner and Kibble worked for the British National Physical Laboratory at Teddington, just outside London. They do refer positively to the American work of R D Cutkosky - which even I've heard of - but they do mention that this work is "described in a somewhat piecemeal fashion in articles in various journals".

Not every National Lab with gigabucks to spend knows how to spend it well - they wouldn't have talked to you if they did.

National Labs concentrate their attention on the show-stopping problems. Liquid helium levels can be controlled in all sort of ways and most them work perfectly adequately.

The less able members of the laboratory get stuck with dealing with the less important problems.

Silly me, building stuff for all those labs. I should have refused and sent them to you.

John Larkin Highland Tech Glen Canyon Design Center Lunatic Fringe Electronics

It wasn't silly of you to take their money and build stuff that you thought was was good enough, and it might not have been silly of them to give the work to you, rather than to take the time to find somebody who actually was as competent as you think you are.

People like that do seem to be thin on the ground and pretty busy. Finding them isn't all that easy either.

A lot of my time a Cambridge Instruments was devoted to up-grading circuits that were more or less good enough and replacing them with something better - it usually happened when something else had been up-graded and that showed up the short-comings of other parts of the system.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required