Colcroft-Watson multiplier would probably be the easiest. Vladimir Vassilevsky...
S
Spehro Pefhany
Well, we won't be replacing an LN200 with it anytime soon. ;-)
You read this part?
Temperature data can be enabled by setting the TEMP_EN bit in the CTRL_REG5_XM (24h) register to 1.
And this part?
Both OUT_TEMP_H_XM and OUT_TEMP_L_XM registers must be read.
Sounds like there's a couple of necessary conditions for it to work.
Also
TEMP_EN Temperature sensor enable. Default value: 0 (0: temperature sensor disabled; 1: temperature sensor enabled)
Best regards, Spehro Pefhany
"it's the network..." "The Journey is the reward"
speff@interlog.com Info for manufacturers: http://www.trexon.com
Embedded software/hardware/analog Info for designers: http://www.speff.com
B
bloggs.fredbloggs.fred
There's only 67 registers and most of it is pretty mundane stuff. Skimpy little datasheet is 80% bits and pieces "ported" from earlier products. ST made it simple enough for a caveman, well almost.