A number of designs exist of preamplifiers to measure power supply, zener,
LED, and other noise sources. These generally have a large input cap to
isolate the source voltage from the input of the preamp. A large capacitor
can have huge leakage, which can disrupt the input bias of the preamp.
Here is a proof-of-concept approach that doesn't use a large series input
cap. Instead, the preamp input is direct coupled to the source. It uses a
LT1028, which has an unparalleled low frequency noise corner and very low
input noise.
The gain is set to 40dB. The low frequency response is determined by large
electrolytics in the feedback path, but the leakage current of the capacitors
has minimal effect on the output due to the design.
As in other approaches, multiple preamps could be paralled for very low input
noise. The feedback resistors could be adjusted for minimum overall noise.
You can download the LTspice ASC and PLT files here:
https://tinyurl.com/9n2cfmcj
LED, and other noise sources. These generally have a large input cap to
isolate the source voltage from the input of the preamp. A large capacitor
can have huge leakage, which can disrupt the input bias of the preamp.
Here is a proof-of-concept approach that doesn't use a large series input
cap. Instead, the preamp input is direct coupled to the source. It uses a
LT1028, which has an unparalleled low frequency noise corner and very low
input noise.
The gain is set to 40dB. The low frequency response is determined by large
electrolytics in the feedback path, but the leakage current of the capacitors
has minimal effect on the output due to the design.
As in other approaches, multiple preamps could be paralled for very low input
noise. The feedback resistors could be adjusted for minimum overall noise.
You can download the LTspice ASC and PLT files here:
https://tinyurl.com/9n2cfmcj
--
The best designs occur in the theta state. - sw
The best designs occur in the theta state. - sw

Re: Low Noise Direct Coupled Preamp
Phil Allison wrote:

Nah, trying to do this with AC coupling is useless in the sub-audio range.
The tempco of polypropylene is about +200 ppm/K. With even 1V DC on it,
that cap will drift -0.2 mV/K. To get down to the ~1 nV/sqrt(Hz) level,
the temperature fluctuations have to be below 5 uK/sqrt(Hz). Pretty
tough at low frequency.
And then there's the drift, which is even worse.
Cheers
Phil Hobbs

Nah, trying to do this with AC coupling is useless in the sub-audio range.
The tempco of polypropylene is about +200 ppm/K. With even 1V DC on it,
that cap will drift -0.2 mV/K. To get down to the ~1 nV/sqrt(Hz) level,
the temperature fluctuations have to be below 5 uK/sqrt(Hz). Pretty
tough at low frequency.
And then there's the drift, which is even worse.
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp
========================

** Crapology.
The OP only spoke of cap leakage - fuckhead.
--------------------------------------------------------------------------

** Likely never matter in real applications involving DC PSUs, zeners and the like.
Wot a colossal wanker you are.
........... Phil

Re: Low Noise Direct Coupled Preamp
On Thursday, February 25, 2021 at 6:36:40 PM UTC-5, Phil Hobbs wrote:

Who wants 1 nV below a hertz or so? ,I once had this idea to measure 1/f noise
from DC, so I made a bridge (All 1 k ohm 0.1% MF resistors to start* IIRC) And all I remember
was DC drifting one way or the other.. (Thermal effects maybe) I didn't spend much time on it.
George H.
* replace one with carbon composite later.


Who wants 1 nV below a hertz or so? ,I once had this idea to measure 1/f noise
from DC, so I made a bridge (All 1 k ohm 0.1% MF resistors to start* IIRC) And all I remember
was DC drifting one way or the other.. (Thermal effects maybe) I didn't spend much time on it.
George H.
* replace one with carbon composite later.


Re: Low Noise Direct Coupled Preamp
George Herold wrote:

At frequencies for which the thermal mass approximation still works, the
amplitude of thermally-forced noise and drift goes as 1/f. That extends
the sensitivity up to surprisingly high frequencies, especially in a
powered test circuit with people moving around.
Making good measurements at sub-hertz frequencies is surprisingly hard.
Cheers
Phil Hobbs

At frequencies for which the thermal mass approximation still works, the
amplitude of thermally-forced noise and drift goes as 1/f. That extends
the sensitivity up to surprisingly high frequencies, especially in a
powered test circuit with people moving around.
Making good measurements at sub-hertz frequencies is surprisingly hard.
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp

I've used Phil's technique, a 1 uF film cap and big R.
to measure power supply noise. It worked fine...
(I still remember being surprised the big R didn't add to the noise,
mostly dominated by the opamp in this case.)

Grin, for the above case if I tried to measure the power supply noise below
~100 Hz, at maximum gain, it would start to oscillate as soon as I looked at it
sideways.
George H.


Re: Low Noise Direct Coupled Preamp
On Thursday, February 25, 2021 at 10:27:35 PM UTC-5, snipped-for-privacy@gmail.com wrote:

Oh in this case the supply was to bias other noise measurements.
Powering leds or light bulbs for shot noise measurements.
or just resistors...
Mostly with 8nV/rtHz opa134's, with some averaging you can measure ~1 nV.
(you need a switch to ground the front end and measure the noise w/o the supply.)
George H.


Oh in this case the supply was to bias other noise measurements.
Powering leds or light bulbs for shot noise measurements.
or just resistors...
Mostly with 8nV/rtHz opa134's, with some averaging you can measure ~1 nV.
(you need a switch to ground the front end and measure the noise w/o the supply.)
George H.


Re: Low Noise Direct Coupled Preamp
Phil Allison wrote:

If all you're attaching is a mic and some speakers, that's true. In an
instrument that 16 nV/sqrt(Hz) could easily degrade the noise floor by
25 dB. (Discrete circuitry is de rigueur for the lowest noise
applications, and generally doesn't have much PS rejection.)
Cheers
Phil Hobbs

If all you're attaching is a mic and some speakers, that's true. In an
instrument that 16 nV/sqrt(Hz) could easily degrade the noise floor by
25 dB. (Discrete circuitry is de rigueur for the lowest noise
applications, and generally doesn't have much PS rejection.)
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp
George Herold wrote:

Sure, I have too. In his frequency range and noise levels there's no
reason not to. But a dedicated noise tester really needs to be able to
go below 0.1 Hz IME. Lots of voltage references specify noise in that
range, and below a few hertz the tempco of the capacitor can easily be a
serious limitation.
The effect is so large--like 1 mV/K on a 5V supply-- that you don't have
to slew the temperature of the inside of the cap. Just the outer foil
is enough to worry about, and that changes surprisingly fast with air
currents and so on.
Cheers
Phil Hobbs

Sure, I have too. In his frequency range and noise levels there's no
reason not to. But a dedicated noise tester really needs to be able to
go below 0.1 Hz IME. Lots of voltage references specify noise in that
range, and below a few hertz the tempco of the capacitor can easily be a
serious limitation.
The effect is so large--like 1 mV/K on a 5V supply-- that you don't have
to slew the temperature of the inside of the cap. Just the outer foil
is enough to worry about, and that changes surprisingly fast with air
currents and so on.
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp

The typical 1/f corner frequency of the LT1028 is 3.5 Hz. This limits the
usable low frequency response of the preamp to 1Hz or so. Multiple
sections can be added in parallel to reduce noise, but this quickly runs
into practical limits of 1/sqrt(N).
The value of the preamp is measuring sources that have greater flicker
noise than the preamp. Examples are low noise power supplies, zener diode
noise, IR LED noise, etc.
--
The best designs occur in the theta state. - sw
The best designs occur in the theta state. - sw

Re: Low Noise Direct Coupled Preamp
Steve Wilson wrote:

It gradually degrades the noise floor, but it takes more than two
decades for that 1/f contribution to get up to the flatband of Phil A's
noiseless TL084.
3.5 Hz / (16 nv /1 nV)**2 = 0.014 Hz.

If you have a squint at the battery paper I linked to, you'll find a
discussion of the two-channel correlation technique. With CMOS
amplifiers, you can get the noise floor down way below the amplifier
noise, though of course you have to average for awhile if you want it to
work well at very low frequency.

Sure. But there are a lot more bogies down in the very low baseband
than just flicker noise.
Cheers
Phil Hobbs

It gradually degrades the noise floor, but it takes more than two
decades for that 1/f contribution to get up to the flatband of Phil A's
noiseless TL084.
3.5 Hz / (16 nv /1 nV)**2 = 0.014 Hz.

If you have a squint at the battery paper I linked to, you'll find a
discussion of the two-channel correlation technique. With CMOS
amplifiers, you can get the noise floor down way below the amplifier
noise, though of course you have to average for awhile if you want it to
work well at very low frequency.

Sure. But there are a lot more bogies down in the very low baseband
than just flicker noise.
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp

[...]

I don't understand your calculation.
The typical LT1028 hits 1nV/root(Hz) at 10 Hz, and 0.8nV/root(Hz) at 100
Hz.
The preamp starts to roll off around 1 Hz, so 0.014 Hz is well below the
cutoff frequency.

Fred Walls has published an amazing number of papers on low noise
techniques.
The system illustrated in Fig. 1 requires duplicate identical noise
sources, and duplicate amplifiers with positive and negative inputs to
take the difference between the two noise sources.
The low noise preamp described here has only a single input. It cannot
take the difference between two inputs.

The preamp starts to roll off around 1 Hz. It does not respond to very low
frequencies.

--
The best designs occur in the theta state. - sw
The best designs occur in the theta state. - sw

Re: Low Noise Direct Coupled Preamp
Steve Wilson wrote:

The 1/f noise goes up as, well, 1/f. That's in terms of power, so to
get N times more noise _voltage_, you go N**2 times lower in frequency
to get N**2 times more PSD.

That's just on account of your circuit topology and parts values, not
the limitations of the op amp.

Again, that just requires moving a few wires or changing some component
values.
Cheers
Phil Hobbs

The 1/f noise goes up as, well, 1/f. That's in terms of power, so to
get N times more noise _voltage_, you go N**2 times lower in frequency
to get N**2 times more PSD.

That's just on account of your circuit topology and parts values, not
the limitations of the op amp.

Again, that just requires moving a few wires or changing some component
values.
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp

[...]



I don't want to get more noise power. This calculation has no meaning in
this application.
[...]

I don't see how moving a few wires would change the low frequency response.
I do not want to measure very low frequencies.
The 1/f noise would dominate the measurement and make it useless. I want
to start rolling off around 1 Hz, or even a bit higher. Fotunately, the
design of this preamp makes it very easy to change the upper and lower
cutoff frequencies.
A capacitive coupled preamplifier would suffer extreme transients if the
input capacitor value is changed. The preamplifier could be destroyed if
the capacitor was suddenly connected to a large voltage source.
Direct coupling as shown here changes the transient into a simple slew rate
issue.
I could make a NIST correlator to measure very low frequencies, but that is
a different ball game and out of the scope of this preamplifier,

--
The best designs occur in the theta state. - sw
The best designs occur in the theta state. - sw

Re: Low Noise Direct Coupled Preamp
Steve Wilson wrote:

<>
You wrote,
"The typical 1/f corner frequency of the LT1028 is 3.5 Hz. This limits
the usable low frequency response of the preamp to 1Hz or so."
But that isn't true, as I demonstrated. Your circuit is your circuit,
and does what you want it to, but it isn't the only one in the world.
That's a separate point.
There's been a lot of fuzzy reasoning in this thread, basically along
the lines of "my filter cuts off everything past the 3 dB point." When
the interfering signal is very strong, as the tempco forcing in biased
capacitors is, you have to be way down the skirts of the filter before
it becomes negligible.
Cheers
Phil Hobbs

<>
You wrote,
"The typical 1/f corner frequency of the LT1028 is 3.5 Hz. This limits
the usable low frequency response of the preamp to 1Hz or so."
But that isn't true, as I demonstrated. Your circuit is your circuit,
and does what you want it to, but it isn't the only one in the world.
That's a separate point.
There's been a lot of fuzzy reasoning in this thread, basically along
the lines of "my filter cuts off everything past the 3 dB point." When
the interfering signal is very strong, as the tempco forcing in biased
capacitors is, you have to be way down the skirts of the filter before
it becomes negligible.
Cheers
Phil Hobbs
--
Dr Philip C D Hobbs
Principal Consultant
Dr Philip C D Hobbs
Principal Consultant
We've slightly trimmed the long signature. Click to see the full one.

Re: Low Noise Direct Coupled Preamp

Yes, it is a single pole filter. The bandwidth is measured at the -3dB
points, as is normal for filters. If you know it is a single pole and the
3dB point, you can easily find the response at any point on the curve. The
LTspice PLT file gives you that curve.
A single pole filter has a pretty crappy rolloff, but that is not a problem
in this application. The measurement time is too fast for the capacitor to
change temperature and affect the reading.
I do not need much low frequency response. All I need is to find the corner
frequency and the noise floor.
The corner frequency is where the noise starts to rise at about a 45 degree
angle. The 1/f noise is pretty much the same for most sources, so once you
have the corner frequency, there is not much more to learn.
Measurement speed is also an issue. I may want to sort through dozens or
hundreds of LEDS to find the best brand and the quietest ones. If the
filter frequency response is too low, I will have to wait longer for the
measurement to settle.
The noise floor is much more significant. This separates the noisy sources
from the quiet ones. The quiet ones is what I am after, so that is the main
emphasis. The noise floor occurs at a much higher frequency than the corner
frequency, so low frequency response is not a major concern.
I expect the noise sources to be much greater than the noise floor of the
instrument. If I need a lower noise floor, I can always use multiple units
in parallel, up to the practical limit set by 1/sqrt(N).
Temperature coefficient of the capacitors is not a concern. The instrument
must be in a shielded box to eliminate RFI. This also reduces the random
air currents present on the outside. If tempco becomes an issue, I can dump
the circuit in a jar of mineral oil to minimize any fluctuations.
Having a higher rolloff frequency also minimizes any effect of capacitor
tempco. The cutoff frequency is simply too high for the capacitor to change
temperature much and affect the reading. If it still becomes an issue, I
can raise the cutoff frequency to allow less time for the capacitor to
change value.
All I need is to be able to find the corner frequency, which may be in the
tens or hundreds of Hz. Not much is going to happen to the capacitor
temperature in that short of time.
I have presented an approach that eliminates the capacitor coupling at the
input, that eliminates any danger of destroying the base junction of a
bipolar or jfet due to current surge, that settles quickly, is easy to
change the rolloff frequencies, has reasonably low noise due to the LT1028,
and is simple and inexpensive.
And did I mention - it gets rid of the coupling capacitor at the input.
It was also designed in the Theta state.
--
The best designs occur in the theta state. - sw
The best designs occur in the theta state. - sw
Site Timeline
- » OT A modest proposal
- — Next thread in » Electronics Design
-
- » Microwave and Millimeter Wave Power Beaming
- — Previous thread in » Electronics Design
-
- » Auction in Fremont, ca NOW
- — Newest thread in » Electronics Design
-
- » Amateur electronics in danger due to lack of DIP ICs
- — Last Updated thread in » Electronics Design
-
- » PCA9957 defektes SPI
- — The site's Newest Thread. Posted in » Electronics (German)
-