The ruggedized approach uses an SCR latch. The timing components are the
2.2U and 2.2M. If the circuit is switched on when the 2.2U is discharged, T1 is triggered immediately and grounds out the gate of T2 preventing it from triggering. The strobe lamp remains OFF, and the 2.2U charges to the battery voltage. When SW is turned off, T1 turns off and 2.2U discharges very slowly through the 2.2M with a 6 second time constant. If SW is turned on before the 2.2U has discharged to approximately 6V, T1 is prevented from triggering by the zener diode, ZD, and T2 is now allowed to trigger and activate the STROBE lamp. View in a fixed-width font such as Courier.. . SW >---+------------------------------------------+ . | | . V strobe . - lamp . | | . +----------------[1K]----+----------+ +-----+ . | | | | | . [1K] | | | | . | | | | | . V | | | | . - | | | | . | [100] | | | . +----+ | | | | . + | | | | T2 | | . === [2.2M] | | --- | . 2.2U| | +-[1K]-+---------\\ / | . +----+----[100K]-----+ | | | --- | . | | | | | | | . | ZD |T1 | | | | | . | 6.2V | --- [1K]=== | [100] . +------|