HELP, I have non-linear gain in two channels

Oct 03, 2007 10 Replies

I have two identical 3 stage active band pass filters consisting of 3 op amps each. The problem is that I get varying gain in the channels depending on the input signal level.



For a test I ran the same signal to both channels at the same time and sample the output from each channel. Those sampled signal are then adjusted so the static gain is the same for both channels. And then the bias is adjusted.



If I then plot the signals they seem to be exactly the same. But if I plot the deferens between the channels I can se the sometimes ch1 is a bit more than ch2 and vise versa. It's dependent of the input signal amplitude.



What can cause this, any tips?



In my application it is important that both channels change the same percentage. If the input signal to ch1 and ch2 attenuates 1% the outputs from ch1 and ch2 must attenuate 1% also.



ADC's can have small non-linearity errors. So maybe I'm going to connect one band pass signal to both ADC's to check if I get the same result.



What's the Q of the stages? What type of bpf? What frequency ranges, DC to 1Hz, or DC to 0.5C +- 3dB

Martin

Poke around with an oscilloscope. One of the stages is clipping... typical for band-pass filters (may have internal node gains approaching "Q", depending on filter architecture).

...Jim Thompson

| James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC\'s and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | | http://www.analog-innovations.com | 1962 | America: Land of the Free, Because of the Brave

How big is the variation?

If it is bandpass, then it is AC. If it is AC, why bias does matter?

Before searching into the complicated problems, I would check for the simple stuff. It could be the power frequency or some other noise picked up by the channels in the different proportion. It could also be the effect of cross coupling between the channels. It could be the bad voltage references for the ADCs.

Vladimir Vassilevsky DSP and Mixed Signal Design Consultant

formatting link

I wouldn't have thought it possible that 2 channels of 9 opamps and shed loads of passive components are ever going to match within 1%. If you're plotting the deferens on a cycle by cycle basis then tiny phase shifts will give big errors. Even with an RMS calculation for each channel there will be differences, due to the numerous capacitors changing their values slightly with differing signal levels. God forbid you using anything remotely like ceramic caps. These can offer a (useful?) 2X value change for a 2X signal change.

I agree with Jim, you are likely seeing the effects of clipping.... another possibility, see what the GBW product is on the op-amps you're using and if it is sufficient for the application.

darn Q's always get in the way, Crom

More info

Hello again

I ran a test today. I connected the signal from one of the band pass channels to both AD converters so they receive the same signal. The gain difference was almost totally gone. I hade only a small gain difference which I think is the ADCs linearity error. The dynamic gain is acceptable.

So the dynamic gain "fault" is located to the band pass filters.

And, yes, I use ceramic capacitors.

It may not be readily apparent in the output. Check internal nodes.

...Jim Thompson

| James E.Thompson, P.E. | mens | | Analog Innovations, Inc. | et | | Analog/Mixed-Signal ASIC\'s and Discrete Systems | manus | | Phoenix, Arizona Voice:(480)460-2350 | | | E-mail Address at Website Fax:(480)460-2142 | Brass Rat | | http://www.analog-innovations.com | 1962 | America: Land of the Free, Because of the Brave

(just my luck for you to have used hand selected, non commercial, NPO types in a computer optimised R.F. BP arrangement, running at 1V5, so ignore the following. Others may find it of passing interest :)

'Low K','COG', 'NP0', ceramics are nice but only run a few hundred pF and can be fine for many R.F uses. Leaves the 'medium K' and 'high K' types which get worse all the way up to about 100nF. I've seen a lot of talk here but no hard numbers, so stuck a 100nF (worst case, high K) 100nF across a variable DC supply and measured it. Problems immediately turned up as I couldn't finger a 100nF cap'. They were all showing 90nF. Turns out they are "100nF" but sunshine (rare in UK) was warming the room up to 24degC and the appalling tempco of these things had caused the value shift. (body heat from 2 fingers dropped C value to 65nF!). DC bias voltage C value (at 24degC)

0v 90nF 1V 89nF 2V 86nF 4V 78nF 8V 61nF 16V 39nF 30V 18nF (ie 18% of marked value!) (The 'bias' can be static DC or the signal itself. )

Cap' was so p*** poor, that for confirmation I knocked up this L.F. voltage controlled oscillator. ___ ,---|___|---, | 22k | | | | | | 1|\\ 2 | o----| >O---o-----o Frequency Out | |/ | CD40106 (hex schmidtt) | (12V supply) --- --- 470nF 100k | ___ | 0-12V o-----|___|----o DC Control | | --- o --- | | 100nF ceramic === === 0V 0V (created by AACircuit v1.28 beta 10/06/04

formatting link

Control V Frequency

0 840Hz 2V 843Hz 4V 920Hz 6V 1029Hz 8V 1152Hz 10V 1295Hz 12V 1443Hz (30V 2840Hz)

(As a final insult, the cap' ESR measured 47ohms at 1kHz, suggesting any filter resistors need to be >4k7). Basically for filter use, I'd be incined to use -anything- other than ceramics

I still love ceramic caps though. They're small, cheap and are excellent for decoupling use.

Thank youy for your interesting reply :-) I will try to change to other kind of caps.