Best way to reject 50Hz or 60Hz mains with ADS1118

The device offers the following sampling rates on the delta-sigma ADC:

8 16 32 64 128 250 475 860

The 16/sec conversion rate would alone reject 60Hz fairly accurately, but there is no similar option for 50Hz.

Sampling at the highest speed (860/sec) and accumulating 14 or 17 readings respectively (and then dividing the total by the number of samples), would do it, but then we don't get the natural noise rejection of the slow ADC reading rates.

It seems that the best compromise is: For 60Hz rejection, use the 16/sec reading rate directly. The averaging feature is still available but is not necessary for 60Hz rejection. For 50Hz rejection, use the 250/sec reading rate and average last 5 readings.

However, I can't get my head around whether the 50Hz option will really work.

It would obviously work if one added up 5 readings and divided it by 5

- a process which would take 20ms and that would be exact. Then you start with a freshly initialised accumulator for the next 5. So the system would deliver one reading every 20ms, only.

But will running (what I think is called) a FIR filter, with the last

5 readings held in a FIFO queue, have the same 50Hz rejection effect? That delivers readings every 4ms.

I think it will work because the queue will contain 20ms' worth of readings.

Many thanks for any insight. It's quite a subtle question!

Reply to
Peter
Loading thread data ...

Yes. It doesn't matter where in the cycle you start--it just matters that you stop exactly a whole number of cycles later.

Can you dork the clock rate?

Cheers

Phil Hobbs

--
Dr Philip C D Hobbs 
Principal Consultant 
ElectroOptical Innovations LLC / Hobbs ElectroOptics 
Optics, Electro-optics, Photonics, Analog Electronics 
Briarcliff Manor NY 10510 

http://electrooptical.net 
http://hobbs-eo.com
Reply to
Phil Hobbs

You'd better to keep the 50 or 60 Hz out of the inputs. The data sheet is extremely careful to not specify any tolerance for the internal oscillator frequency, and the filter nulls are pretty steep.

--

-TV
Reply to
Tauno Voipio

Although it does give a new reading every 4ms they are statistically correlated to previous readings until the buffer contains entirely fresh raw data so you really have only one new independent measurement every

20ms. The cancellation scheme works so long as you choose a measurement averaging period that is an exact multiple of the mains period.

The first common one for 60Hz and 50Hz is 10Hz or 100ms of averaging.

It depends how often you need samples which is the best tactic for minimising mains interference when digitising weak signals.

- Regards, Martin Brown

Reply to
Martin Brown

On a sunny day (Mon, 28 Oct 2019 16:26:24 +0000) it happened Peter wrote in :

Filtering BEFORE sampling is the way to go.

Reply to
Jan Panteltje

Preventing interference pickup is always worthwhile but when you are looking for the ultimate performance you have to accept that apart from out in a field far away from any mains wiring there is always going to be some small amount of mains noise magnetically coupled to your kit.

Solartron 7060 DVMs used to have swappable crystals so that their sampling time could be made mains synchronous on all ranges.

--
Regards, 
Martin Brown
Reply to
Martin Brown

On a sunny day (Tue, 29 Oct 2019 10:47:18 +0000) it happened Martin Brown wrote in :

I already wrote that, but decided not to post it as it does possibly not 100 % apply for this case but in general: Suppose you sample at _exactly_ the mains frequency and you take 1 sample at the time (every 20 mS where we live). If you sample at the moment of that very common repetitive spike then you consistently get the value of that spike...

Better is then to have some frequency difference and do signal processing after digitizing. Filtering mains _and_ its harmonics before digitizing is much better eliptical filter:

formatting link
top link.

Spikes are always a problem, wide spectrum ... but I gues everybody knows that.. Mains is NOT clean.

Reply to
Jan Panteltje

But these DACs are typically integrators over a period rather than flash DAC converters of the instantaneous voltage so averaging over the mains cycle period works pretty well to eliminate it. You might get an unlucky reading every now and then as local crystal 50Hz beats against mains.

It never was but it is made worse by cheap and nasty SMPS.

--
Regards, 
Martin Brown
Reply to
Martin Brown

On a sunny day (Tue, 29 Oct 2019 16:50:57 +0000) it happened Martin Brown wrote in :

ADCs DAC stands for Digital To Analog

Reply to
Jan Panteltje

[to the OP] But of course to achieve good rejection at 50Hz, the weights/coefficients of the FIR filter need to be chosen properly (e.g. one tap 1 and the rest zero is obviously no good).

For example, all coefficients the same, i.e. a running average would work, or two equal non-zero coefficients for taps exactly 10ms apart and the rest of the coefficients zero would work, etc. The best choice of coefficients might depend on whether rejection of other frequencies (such as harmonics) is desired, and what step response you need. This is all fairly straightforward to simulate, e.g. in Octave or Matlab.

Reply to
Chris Jones

TYpoe

--
Regards, 
Martin Brown
Reply to
Martin Brown

Great - thank you.

Not on this chip. But yes that would have been an interesting tactic, too.

I do have a lowpass filter on the input. It is 2.2uF ceramic and 2k2. This is followed by a TLV2333 (chopper stabilised op-amp) voltage follower, because the ADS1118 doesn't have a particularly high Zin. I can't up the lowpass filter components much for various reasons.

To get a really good lowpass filter at 50Hz would take a lot of components.

Reply to
Peter