Spend you money on a GPS-based super-accurate 10MHz reference to use all around your lab.
Spend you money on a GPS-based super-accurate 10MHz reference to use all around your lab.
We already have some good 10 MHz sources. But it's a nuisance to have to connect a small, portable counter to a big reference source.
Why a grand for a TCXO?
John
It should not be. Run some dedicated cables, put on a particular color of heat shrink, leave them there like air hoses or electrical outlets.
Distributing 10 MHz all over two floors of a building would be a major project... just for the benefit of one Agilent counter. Ethernet was bad enough.
John
we did that at the capacitor company I consulted at on the side.
GPS time base receiver (10 mhz output), into a distribution amplifier with isolated outputs (20 count). each rung went to a work station to be used as the reference for capacitor testers.
I'm sort of surprised that you only have one thing (which you don't even have, if I understand correctly, since you don't want to buy it without the OXCO, and the OXCO is overpriced) that would benefit from easy access to a reference frequency, especially since you have already bothered to get in several reference frequency sources.
So they can sell the 'stripped' version for a grand cheaper to the penny pinchers? Maybe something like that.
The way I read it, I assumed John was talking about pulling all that cable.
Thanks, Rich
Yes, I got that. I just find it hard to justify not doing so as "it's only for this one meter I haven't bought, so why bother."
Obviously there _are_ other things which he does have that benefit from good references, or he would not have any of those, much less several.
Thus, a one-time painful cable-pull-fest would make all those applications, and any future ones (even if he never buys the particular counter in question) easy, rather than a hassle. It's sort of like "Why go to the bother of running all that pipe, when I can get water in a bucket?" Or "Why go to the bother of running all that pipe, when I can drag out a portable air compressor and a hose if I need compressed air?"
The way you use things, be they water, compressed air, or 10MHz reference frequencies, changes depending on how much of a pain it is to access them. I suspect that the price of one new counter without OXCO might cover a fleet of older ones from *B*y that will be just fine if they are fed a known-good reference. Some signal generators can also take an external reference for greater precision, if there's one coming to the bench anyway.
Enough, I'll stop here.
We have a bunch of HP5370B's, which are 20 ps single-shot time interval counters, that also do frequency to 100 MHz. They all seem to stay within 30-50 ppb of the rubidium, so they don't really benefit from an external reference. But they're 4U rackmount beasts, not something I want in my office mini-lab. I'm in the market for a nice little "universal" counter, preferably new, and haven't found anything really suitable.
My Keithley 2100 DVM is a pretty good frequency counter, too, so maybe I'll just wheel over a 5370 when I need something serious.
Heck, my TDS2012 is a pretty good counter, too.
John
Have something to add? Share your thoughts — no account required.