A bit of thimking. Assuming you have a 100 A service at 120/240 V (US standard). The limit feeder drop is 3% or 3.6/7.2 V or maximum Z of = about
0.3 Ohm. 5 V(dc) flowing 0.3 Ohm gives about 16 A. You should be able = to find that with circuit breakers tripping or fuses blowing. =20 If that is not happening you may very well have a measurement error, = where something is causing a false reading on your meter. Try looking at it with an oscilloscope to see what other signals are there.On a sunny day (Thu, 23 Jun 2011 12:50:56 -0700 (PDT)) it happened whit3rd wrote in :
produced,
The rectifier tubes are clear when new, but get colored after many hours of X ray exposure. They are not manufactured colored. There are some pics on the web, if you google.
5 volts doesn't sound reasonable. What DC voltmeter range were you using? You may be seeing voltmeter overload.
John
"John Larkin"
** The OP did not say he actually read any such value an a meter - but in general, you cannot read the DC component of a 120 or 230 volt AC supply with just a DMM set to DC volts.A little bit of AC filtering is needed first - say a 1Mohm resistor and a
2.2 uF film cap in series across the supply, then read the DC voltage on the cap with a DMM.Allow 10% more for the effect of loading from the 10Mohm input of the meter.
I'd be surprised if you see more than 0.5 to 1 volt.
.... Phil
Mercury Vapor rectifier.
As "hifi-tek" said several days ago; it's the tungar lamp rectifier that I was thinking of...
I've never thought of mercury vapor rectifiers as high current/low voltage devices.
I was off the group for a week.
They were used to power subway trains. They can be builkt to about any scale they needed. I've never seen a low current mercury vapor rectifier, and doubt they would be practical.
The classic that I have used was the 866A; good for a few KV but only a few hundred mA.
It would make a lousy detector, wouldn't it? :)