Changing out the cheapy light fixtures that came with the house, I turn the switch off, remove the old fixture, accidentally bump common (white) against frame (green) and breaker popped.



Measure white with DMM... AC-level is a few hundred mV (noise?).



Measure black with DMM... AC-level is even smaller.



Likewise black to white.



Touch black to green... nothing.



Touch white to green... pop.



Do these new breakers have the equivalent of GFCI built-in? ...Jim Thompson


| James E.Thompson | mens | | Analog Innovations | et | | Analog/Mixed-Signal ASIC's and Discrete Systems | manus | | San Tan Valley, AZ 85142 Skype: skypeanalog | | | Voice:(480)460-2350 Fax: Available upon request | Brass Rat | | E-mail Icon at http://www.analog-innovations.com | 1962 | I love to cook with wine. Sometimes I even put it in the food.

Arc-fault breakers? Switch in the wrong side?

Neutral and ground should be bonded at the service panel. Sounds like something is wired wrong.

It is also legal to use a white wire but mark it with black tape to use it as 'LINE' or HOT.

CHeers

Yes, you most likely have GFCI breakers.

joining ground and N at that location should cause a trip, and it seems it's working.. that should work even if the Black wire is dead, due to your light switch being off because the other wires N are still connected to the system. Appliances are suppose to balance the N line or use a transformer, this method will detect a N hitting ground directly when it's not suppose at the user end.

The breaker still has both L1 and L2 alive in it so when N hits ground you have a imbalance. Sounds like it's working fine.

Jamie