PWM test results for Hue White Ambiance, model 591131

Nov 27, 2026 Last reply: 2 hours ago 2 Replies
Jump to replies (2)

Finished running my flicker tests on the Philips Hue White Ambiance bulbs, model number 591131, and the results are not great for anyone like me who is sensitive to PWM. A few days ago I tested the Hue Essential bulbs and those showed almost no flicker, so I figured I'd put the White Ambiance ones thru the same rig for comparison. Clear PWM flicker on these, no two ways about it. The report covers four brightness levels: 100%, 50%, 25% and 1%. Frequencies came in between 2.1 kHz and 4.2 kHz with Percent Flicker from 96.5% up to 100.0%. Each setting got tagged 'Not Recommended', and to be clear that classification comes straight from the Illuminating Engineering Society's technical standard TM-39-25, not my own call on what is or isn't good. The dominant frequency shifting around between brightness levels is typical of PWM dimming. All of this was measured with a flicker meter I built myself, the TLM-110. Happy to finally have a solid low flicker option on hand with the Essential bulbs, since PWM does not treat me well.


I'm one of those people who gets eye strain and a low headache from certain dimming, so a side-by-side of two bulbs from the same brand is exactly the comparison I wanted to see. It's a bit surprising that two lines under the same name behave so differently, and I appreciate that you tied the ratings back to the IES standard rather than leaving it as a personal verdict. That makes it much easier to trust the writeup when I'm deciding what to buy. The Essential bulbs coming out as the low flicker option is good news for my wallet, honestly. I've been putting off swapping the last few dimmable bulbs in my house until I had a solid reason to pick one line over the other, and this gives me one.

One thing I'm curious about: did the Essential bulbs stay clean at the very low end too, or did you only run them at normal brightness levels when you tested them? Low settings are where my eyes seem to pick up on it most, so that's the range I care about before I commit to replacing everything.

I'm new to all this light stuff, so forgive me if this is a dumb question. When you say the flicker percentage was basically maxed out at some settings, does that mean the bulb is flashing on and off really fast, like turning fully dark between pulses? I always assumed dimming just meant the light got softer, not that it was blinking that hard the whole time. Also kind of cool that you built your own measuring gadget for this, that sounds way beyond anything I could put together.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required