Terminal block usage.

Jul 06, 2024 Last reply: 1 year ago 4 Replies

Hello again,



I'll be connecting wires to the terminal block of a motor controller. Two connections will each have two wires as illstrated here.

formatting link
Soldering the pair of wires together will keep them aligned when inserting. I understand that solder creeps. Is solder prohibited in this application? OK if applied sparingly?



Should conductive paste be applied?



Thanks, ... Peter E.



I don't know about legality, but I will never solder wires that are to be clamped. They will loosen over time.

Crimped ferrules seems to be a popular alternative.

Your link bounces a 404, so I can't see exactly what you're talking about.

This can depend on terminal block type/integrity, wire gauge and lead dressing. If in doubt, don't do it - use a connection method and materials that you are comfortable with and know will give reliable service.

RL

Fixed.

formatting link
Thx, ... P.

  • User FidoNet address: 1:396/45 Hello All.
<On 21Jul2024 17:25 snipped-for-privacy@easthope.ca wrote a message to All regarding Re (2): Terminal block usage. >

pe> > Your link bounces a 404, ...

pe> Fixed.

formatting link
Juding from the apparent size of the conductors in your picture, tinning is definitely not recommended. If they're available in a small size, properly crimped wire ferrules would be the most recommended method of making these terminations.

There is too much "compression creep" with tinned wires as I've experienced in the past.

Best regards, Marc Lewis, CET Service Manager Quantum Technologies Service Centre Huntsville, AL USA

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required