Magneto coil construction/ rewind

Mar 05, 2009 0 Replies

Using polythene film canabalised from 0.47uF, 1000V capacitor for interlayer insulation.



0.01mm thick film and 1000V rating, what rating for pulsed rather than DC use in the HT re-winding of a magneto, original interlayer winding paper and cloth and lacquer.


data from the end of

formatting link
for 2.5 thou/mil thickness polythene film



2.5 thou = 0.0635 mm so dividing by 6.35 for 0.01mm
2.7KV for pulse use
2.1KV for DC use

is dielectric strength linearly scaleable? presumably a 50 percent factor of safety in capacitor use for localised compression etc. is the maximum voltage across the insulation double the voltage along one wire winding layer? ie one layer and the return on the other side


Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required