LG Studioworks 520Si monitor; doesn't power up after disconnected the deflection coils

Aug 30, 2005 3 Replies

Hello,



I have a bit of a problem with a LG Studioworks 520Si CRT monitor. I got it today and powered it up, but with no computer or whatsoever attached. Everything seemed to be working fine. The next thing I did (my reasons are unimportant ;-)) was disconnecting the four wires which connect the 2 deflection coils to the big circuit board of the monitor. When I tried to turn it on, the monitor began producing a sort of a 'beep' sound, which repeats itself very quickly (until I pulled the plug :-)). Also, the LEDs on the front except for the power LED are blinking in the same 'rhythm'. I disconnected the power cable and plugged the 4 wires back in, but the problem persists.



I took a look at the board, but I don't see any damaged parts. Has anyone an idea on how I can solve this, or did I just destroy a good monitor (hopefully not :-)).



Thanks in advance.



You probably blew the horizontal output transistor, possibly some related parts along with it. Never randomly pull connectors unless you want to sabotage the equipment.

Met vriendelijke groet,

Maarten Bakker.

Reminds me of a job I was asked to do many years ago at the local TV studio. I had to modify two CTV's so that the picture was the right way when the sets were suspended upside down from the ceiling . Can't recall why they had to do it that way.

As the other poster said, the HOT is probably short, It's the power transistor on a heatsink near the flyback transformer.

Graham. %Profound_observation%