Hey, I recently bought a vx1100 monitor second hand and thje other day went to switch it on and nothing happened. I opened up the monitor and found the fuse had blown. I notcied the fuse in there said t3.15a 250v , although marked on the circuit board was t4a. Ireplaced it with another 3.15 a, which blew straight away, so i replaced with a 5a fuse on the basis that it asks for a 4a and the nearest i had was 5a. The fuse did not blow but the unit does not start, no green l.e.d on the front power switch. no noise , nothing, there were no obvious burns inside the case!, any ideas guys?



cheers muncey



No insult intended but... My idea is you should not be servicing electronics. By describing what you tried as a repair, if the monitor had turned on it would have caused a fire and/or electrical shock hazard. The stickers on the back that state "For service by authorized personnell" or something similar refers to someone who will try to do some basic troubleshooting before replacing a fuse and who will NEVER use a fuse rated higher than required by the manufacturer. The fuse is the first line of defense against a fire and almost never opens unless there is an overload or short-circuit later on in the device.

muncey: Generally, whan a fuse blows in a monitor, it means that there is a short on the primary side of the switching power supply. The power supply is designed so that it can detect an over-voltage or over-current (short) on the secondary side (load side) and automatically shut down. I would check the bridge rectifier (or 4 individual rectifier diodes) and the switching FET (on the heat sink) for shorts. Once in a while, a capacitor will short, but it is somewhat rare. Hope this helps.... John

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required