Units made around 1999, have seen common CRT failures. Model # TXJ2750X/XAC, Chassis # K51A. Units come in with 2SD1880 horizontal output shorted, & CRT arcing orange inside tube, replace horizontal output, set works for a couple of days, & the replaced CRT also starts arcing. Sometimes the CRT's lose the vacuum, other times, they arc, for no aparent reason. Sometimes, if you hit the CRT hard, the problem will show up. Anyone see the exact cause for this fault? High voltage & B + is fine, & horizontal output runs at normal temperature. Dani.
Common Samsung 27" CRT failures.
May 17, 2007
1 Replies
Have you checked the HT and then EHT? excessive HT woill cause excessive EHT. Also tuning components in the line output can cause excessive EHT. This should be around 25-28 KV. If these voltages are ok, maybe you are buying crap tubes?
Cheers Rod