spartan 3E starter kit : usb/jtag write cmdbuffer failed

I am testing uclinux with microblaze (as explain in

formatting link
on spartan 3E starter kit (digilent rev. D) and have configuration nightmare.

tools : ISE 81 EDK 81 / window XP (Xilinx EDK 8.1.02 Build EDK_I.20.4) PC : usb host controler is a via vt6212

I can download design to fpga (i.e. implementation/donload.bit, and numerous other .bit files) but I can't download uclinux image into ram : "write cmdbuffer failed"

I already test with 3 other usb cables, an other usb host controler (I had to buy a new one because with the one integrated to asus mb K8VSE, Impact didn't succeed even to enumerate devices on board) ... any ideas ...

(I hope ISE/EDK 82i I am dowloading has a patch...)

xmd console

-=-=-=-=-=-=-

Checking cable driver. Driver xusbdfwu.sys version: 1018 (1018). Driver windrvr6.sys version = 7.0.0.0.Calling setinterface num=0, alternate=0. DeviceAttach: received and accepted attach for: vendor id 0x3fd, product id 0x8, device handle 0x27b0038 Max current requested during enumeration is 280 mA.

----------------------------------------- IS 280mA NOMINAL (muranaka has only 150 mA ?????)

Cable Type = 3, Revision = 0. Setting cable speed to 750 KHz. Cable connection established. Firmware version = 1018. CPLD file version = 0006h. CPLD version = 0006h.

JTAG chain configuration

-------------------------------------------------- Device ID Code IR Length Part Name 1 01c22093 6 XC3S500E 2 05046093 8 XCF04S 3 06e5e093 8 XC2C64A_VQ44_1532 Assuming, Device No: 1 contains the MicroBlaze system Connected to the JTAG MicroProcessor Debug Module (MDM) No of processors = 1

MicroBlaze Processor 1 Configuration :

------------------------------------- Version............................4.00.a No of PC Breakpoints...............2 No of Read Addr/Data Watchpoints...0 No of Write Addr/Data Watchpoints..0 Instruction Cache Support..........on Instruction Cache Base Address.....0x22000000 Instruction Cache High Address.....0x23ffffff Data Cache Support.................on Data Cache Base Address............0x22000000 Data Cache High Address............0x23ffffff Exceptions Support................off FPU Support.......................off FSL DCache Support.................off FSL ICache Support.................off Hard Divider Support...............off Hard Multiplier Support............on Barrel Shifter Support.............off MSR clr/set Instruction Support....off Compare Instruction Support........off Number of FSL ports..............1 MBsfsl(0)-MDMmfsl(0) Connected..........Yes JTAG MDM Connected to MicroBlaze 1 Connected to "mb" target. id = 0 Starting GDB server for "mb" target (id = 0) at TCP port no 1234 XMD%

downloading image.bin

-=-=-=-=-=-=-=-=-=-=-=

XMD% dow -data images/image.bin 0x22000000 write count != nBytes(0), rc = C0000011. write cmd failed C0000011. write cmdbuffer failed 20000015. write cmdbuffer failed 20000015. write cmdbuffer failed 20000015. write cmdbuffer failed 20000015. write cmdbuffer failed 20000015. write cmdbuffer failed 20000015. XMD%

Reply to
rponsard
Loading thread data ...

don't forget : Always reboot (and halt) windows when something goes wrong...

around midnight I turn off computer, and on again... now it is ok ...

but there is something strange with that usb link...

Reply to
rponsard