iMPACT error : Done did not go high.

Jan 08, 2004 2 Replies

Hi everybody, I have been trying to configurate the Microblaze processor in several boards, I use iMPACT and a JTAG cable to download the bistream to the boards, but the process fails. The following is the result message :


--------------------------------------------------------------------- // *** BATCH CMD : Program -p 2 PROGRESS_START - Starting Operation. Validating chain... Boundary-scan chain validated successfully. Validating chain... Boundary-scan chain validated successfully. '2':Programming device... done. INFO:iMPACT:579 - '2': Completed downloading bit file to device. INFO:iMPACT:580 - '2':Checking done pin ....done. '2': Programming terminated, Done did not go high. PROGRESS_END - End Operation. Elapsed time = 5 sec.



---------------------------------------------------------------------


Somebody has experimented this error?



or



Somebody know what are the common causes of this?


Thanks in advance


check your init_b and prog_b pin. make sure they are not pulled down.

"Mois?s" ??????: snipped-for-privacy@posting.google.com...

I see this error also with a SpartanII design I'm working on. The DONE pin does go high but Impact for some reason is not seeing it. I've had too much other stuff going on to track it down at this time. If I figure it out, I'll let you know. If you find the problem, please post it...

Good luck !!!

Greg Deuerling Fermi National Accelerator Laboratory P.O.Box 500 MS368 Batavia, IL 60510 (630)840-4629 FAX (630)840-5406 Electronic Systems Engineering Group Work: egads_AT_fnal.gov, remove '_AT_'