iMPACT error : Done did not go high.

Hi everybody, I have been trying to configurate the Microblaze processor in several boards, I use iMPACT and a JTAG cable to download the bistream to the boards, but the process fails. The following is the result message :

--------------------------------------------------------------------- // *** BATCH CMD : Program -p 2 PROGRESS_START - Starting Operation. Validating chain... Boundary-scan chain validated successfully. Validating chain... Boundary-scan chain validated successfully. '2':Programming device... done. INFO:iMPACT:579 - '2': Completed downloading bit file to device. INFO:iMPACT:580 - '2':Checking done pin ....done. '2': Programming terminated, Done did not go high. PROGRESS_END - End Operation. Elapsed time = 5 sec.

---------------------------------------------------------------------

Somebody has experimented this error?

or

Somebody know what are the common causes of this?

Thanks in advance

Reply to
Mois?s
Loading thread data ...

check your init_b and prog_b pin. make sure they are not pulled down.

"Mois?s" ??????: snipped-for-privacy@posting.google.com...

Reply to
Jay

I see this error also with a SpartanII design I'm working on. The DONE pin does go high but Impact for some reason is not seeing it. I've had too much other stuff going on to track it down at this time. If I figure it out, I'll let you know. If you find the problem, please post it...

Good luck !!!

--
Greg Deuerling
Fermi National Accelerator Laboratory
 Click to see the full signature
Reply to
Egads

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.